Easy method to simplify 'freehand' subaxial cervical pedicle screw insertion

Authors :
Alexander V Burcev
Olga M Pavlova
Konstantin A Diachkov
Galina V Diachkova
Sergey O Ryabykh
Alexander V Gubin
Source :
Journal of Craniovertebral Junction and Spine, Vol 8, Iss 4, Pp 390-395 (2017)
Publication Year :
2017
Publisher :
Wolters Kluwer Medknow Publications, 2017.

Abstract

Study Design: Technical note. Objectives: The objective of this study is to check out safety and rationality of standardized and fast tricks to select trajectory of subaxial cervical pedicle screw (SCPS) insertion, based on simple angles to bony landmarks. Materials and Methods: Stage 1 – Computed tomography (CT)-morphometric analysis of C3–C7 vertebrae of ten patients with cervical degenerative diseases. Stage 2 – SCPS insertion in 6 cadavers, according to the developed technique (59 pedicle screws). Stage 3 – SCPS insertion in 6 patients, according to the developed technique (32 pedicle screws). Results: CT-morphometric analysis showed that the average length of C3–C7 pedicle channels was 32 mm, the average angle between a pedicle axis and an axis of contralateral lamina - 180°, the average angle between a pedicle axis and plane of a posterior surface of a lateral mass amounted to 90° and the coordinates of an optimal entry point – 2 mm from a lateral edge and 2 mm from an upper edge of the lateral mass posterior surface. During the cadaveric study, 39 screws had a satisfactory position (66.1%), 7 screws permissible (11.9%), and 13 screws unacceptable (22%). During the clinical study, 26 screws (81.25%) had satisfactory position, 4 (12.5%) had permissible position, and 2 (6.25%) unacceptable position. Conclusion: Developed and clinically approved a method for simplicity SCPS insertion is relatively safe and cheap. No doubt, it requires further investigation, but the results of primary analysis allow us to recommend it to wide practical application.

Details

Language :
English
ISSN :
09748237
Volume :
8
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Journal of Craniovertebral Junction and Spine
Publication Type :
Academic Journal
Accession number :
edsdoj.76c70798d004d96961becd770e7da51
Document Type :
article
Full Text :