Análise invasiva e não invasiva do fuso meiótico de oócitos humanos obtidos de ciclos estimulados: dados preliminares Invasive and noninvasive analysis of the meiotic spindle of human oocytes obtained from stimulate cycles: preliminary results

Authors :
Luciana Azôr Dib
Michele Gomes da Broi
Maria Cristina Picinato Medeiros de Araújo
Roberta Cristina Giorgenon
Rui Alberto Ferriani
Paula Andrea de Albuquerque Sales Navarro
Source :
Revista Brasileira de Ginecologia e Obstetrícia, Vol 34, Iss 11, Pp 524-529 (2012)
Publication Year :
2012
Publisher :
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, 2012.

Abstract

OBJETIVOS: Avaliar a concordância entre as técnicas de microscopia de polarização e microscopia confocal na avaliação do fuso meiótico de oócitos humanos maturados in vivo. MÉTODOS: Estudo prospectivo que avaliou oócitos com o primeiro corpúsculo polar extruído obtidos de mulheres inférteis submetidas à estimulação ovariana para realização de injeção intracitoplasmática de espermatozoide. Os oócitos com o primeiro corpúsculo polar extruído foram avaliados por meio da microscopia de polarização e, imediatamente após, foram fixados e corados para avaliação dos microtúbulos e cromatina pela microscopia confocal de alto desempenho. Foram comparadas as técnicas de microscopia de polarização e confocal, de acordo com a visualização ou não do fuso meiótico pela microscopia de polarização e a presença ou não de anomalias meióticas à análise pela microscopia confocal. Foram calculados os intervalos de confiança, o índice de Kappa e a concordância entre as metodologias, considerando a análise da microscopia de imunofluorescência como padrão-ouro para avaliação de normalidade do fuso e distribuição cromossômica oocitária. RESULTADOS: Observou-se que 72,7% dos oócitos em metáfase II com fuso celular não visível à polarização apresentaram anormalidades meióticas à análise confocal e que 55,6% dos oócitos em metáfase II com fuso celular visível à polarização apresentaram-se como oócitos anormais à análise confocal. Somente 44,4% dos oócitos com fuso celular visível à polarização apresentaram-se como normais à análise confocal. A concordância entre os métodos foi de 51,1% (Kappa: 0,11; IC95% -0,0958 - 0,319). CONCLUSÕES: A baixa concordância entre a microscopia de polarização e a confocal na avaliação do fuso meiótico oocitário sugere que a visualização do fuso meiótico de oócitos humanos em metáfase II pela microscopia de polarização tem limitado o valor preditivo de normalidade meiótica oocitária.PURPOSE: To evaluate the concordance between polarization microscopy and confocal microscopy techniques in the evaluation of the meiotic spindle of human oocytes matured in vivo. METHODS: Prospective study that evaluated oocytes with the first polar extruded body obtained from infertile women who had undergone ovarian stimulation for intracytoplasmic sperm injection. The oocytes with the first polar extruded body were evaluated by polarization microscopy and were then immediately fixed and stained for microtubule and chromatin evaluation by high-performance confocal microscopy. We determined the correlation of polarization microscopy with confocal microscopy in the detection of meiotic oocyte anomalies, and we also evaluated the percentage of oocytes with a visible and non-visible cell spindle by polarization microscopy and with meiotic normality and abnormalities by confocal microscopy. Confidence intervals, Kappa's index and concordance between the methodologies were calculated, considering immunofluorescence microscopy analysis as the golden-standard for evaluating normal spindle and oocyte chromosome distribution. RESULTS: We observed that 72.7% of metaphase II oocytes with a nonvisible meiotic spindle by polarization microscopy showed no meiotic abnormalities by confocal analysis and 55.6% of metaphase II oocytes with a visible meiotic spindle by polarization microscopy were found to be abnormal oocytes by the confocal analysis. Only 44.4% of oocytes with a visible meiotic spindle by polarization microscopy were found to be normal by confocal analysis. Concordance between the methods was 51.1% (Kappa: 0.11; 95%CI -0.0958 - 0.319). CONCLUSIONS: The low correlation between polarization microscopy and confocal microscopy in the assessment of oocyte meiotic spindle suggests that visualization of the meiotic spindle of human oocytes at metaphase II by polarization microscopy is not a good indicator of oocyte meiotic normality.

Details

Language :
English, Portuguese
ISSN :
01007203
Volume :
34
Issue :
11
Database :
Directory of Open Access Journals
Journal :
Revista Brasileira de Ginecologia e Obstetrícia
Publication Type :
Academic Journal
Accession number :
edsdoj.7692efc9a4444b469427b5c56c1c871b
Document Type :
article
Full Text :
https://doi.org/10.1590/S0100-72032012001100008