Back to Search Start Over

Adaptation of controlled attenuation parameter (CAP) measurement depth in morbidly obese patients addressed for bariatric surgery.

Authors :
Sosthene Somda
Amandine Lebrun
Hadrien Tranchart
Karima Lamouri
Sophie Prevot
Micheline Njike-Nakseu
Martin Gaillard
Panagiotis Lainas
Axel Balian
Ibrahim Dagher
Gabriel Perlemuter
Sylvie Naveau
Cosmin Sebastian Voican
Source :
PLoS ONE, Vol 14, Iss 5, p e0217093 (2019)
Publication Year :
2019
Publisher :
Public Library of Science (PLoS), 2019.

Abstract

Background and aimThe controlled attenuation parameter (CAP) using FibroScan (Echosens, Paris, France) M or XL probe has been developed for liver steatosis assessment. However, CAP performs poorly in patients with high body mass index. The aim of our study was to assess whether CAP is overestimated using the standard XL probe in patients with morbid obesity, and in the case of an overestimation, to reprocess the data at a greater depth to obtain the appropriate CAP (CAPa).Patients and methodsWe conducted an observational prospective cohort study on a total of 249 severely obese patients admitted to our institution to undergo sleeve gastrectomy. Patients had a liver biopsy performed during the surgery and a CAP measurement during the 15 days preceding biopsy. Patient files were reprocessed retrospectively by an algorithm, blinded to the patients' clinical data. The algorithm automatically assessed the probe-to-capsula distance (PCD) by analysing the echogenicity of ultrasound signals on the time-motion mode. In the case of a distance >35 mm, the algorithm automatically selected a deeper measurement for CAP (CAPa). When PCD was less than 35 mm, the measured CAP was considered as appropriated (CAPa) and no further reprocessing was performed.ResultsCAP recording was not performed at a sufficient depth in 130 patients. In these patients, the CAPa obtained at the adapted depth was significantly lower than CAP (298±3.9 versus 340±4.2 dB/m; p< 0.0001) measured at the standard depth (35 to 75 mm). Multiple linear regression analysis revealed that both body mass index and hepatic steatosis were independently correlated with CAP values. After reprocessing the CAP in patients with PCD > 35 mm, steatosis stage was the only parameter independently correlated with CAP values. For the diagnosis of steatosis (S≥1), moderate to severe steatosis (S≥2) and severe steatosis (S = 3), the AUROC curves of CAPa (measured CAP in patients with PCD35 mm) were 0.86, 0.83 and 0.79, respectively. The Obuchowski measure for the diagnosis of steatosis was 0.90±0.013.ConclusionCAP was overestimated in a half of morbidly obese patients using an XL probe, but CAP can be performed correctly in these patients after adapting the measurement depth.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
14
Issue :
5
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.752c2a0263994f12909ee194f9cba3a7
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0217093