Back to Search Start Over

Use of Cobra External Fixator for treatment of Distal Radius Fractures

Authors :
Niraj Ranjeet
Pratyenta Raj Onta
Krishna Sapkota
Pabin Thapa
Krishna Wahegoankar
Upendra Jung Thapa
Source :
Asian Journal of Medical Sciences, Vol 9, Iss 6, Pp 84-89 (2018)
Publication Year :
2018
Publisher :
Manipal College of Medical Sciences, Pokhara, 2018.

Abstract

Background: Distal radius fractures are one of the commonest injuries only after clavicle fractures. These fractures poses challenges to the treating surgeons as a result of which these fractures are sometime treated unacceptably and leads to poor outcome. Among various treatment options for these fractures wrist sparing Cobra external fixator is one of the options with an impressive stability and outstanding functional outcomes. Aims and Objectives: To determine whether this system can achieve adequate reduction of a variety of DRF, is able to maintain reduction despite hand and wrist movements, whether it compromises hand and wrist functions and leads to long term problems. Materials and Methods: From July 1, 2016 - June 30, 2017, all skeletally matured patients with acute distal radius fractures (AO-A2, B1, C1, C2) were adequately reduced and fixed with Cobra ex-fix. Immediately post-op patients were encouraged to start range of motion of the wrist as the pain decreased. The patients were followed up in 2,4 and 8 weeks and were analyzed clinically, radiologically, their functional outcomes and any complications. Results: Twenty-two patients were included in our study. Nine were males and 13 were females. Using the AO classification, 15 were classified as A2, 2 were B1, 3 were C1, and 2 were C2. The mean number of weeks the cobra fixator was maintained was 5.3 weeks. The Cobra ex-fix was able to achieve excellent maintenance of radial height and radial inclination and good maintenance of dorsal tilt. Recovery of functional activities according to Gartland and Werley’s functional scoring system was good to excellent in all patients at 8 weeks follow-up. Conclusion: The Cobra external fixation system is an outstanding device for use in fractures of the distal radius. It achieves superior anatomic correction and is dependable in maintaining fracture reduction even with hand and wrist use.

Details

Language :
English
ISSN :
24679100 and 20910576
Volume :
9
Issue :
6
Database :
Directory of Open Access Journals
Journal :
Asian Journal of Medical Sciences
Publication Type :
Academic Journal
Accession number :
edsdoj.74cf5cecb2a48ecb9a16b1a0c880478
Document Type :
article
Full Text :
https://doi.org/10.3126/ajms.v9i6.20594