Back to Search Start Over

Feasibility and Safety of Very-Low Contrast Combined Ringer's Solution in Optical Coherence Tomography Imaging

Authors :
Tao Chen
Huai Yu
Lijia Ma
Chao Fang
Haibo Jia
Huimin Liu
Maoen Xu
Donghui Zhang
Guang Yang
Shuangyin Zhang
Jincheng Han
Guo Wei
Yanchao Liu
Jingbo Hou
Bo Yu
Source :
Frontiers in Cardiovascular Medicine, Vol 9 (2022)
Publication Year :
2022
Publisher :
Frontiers Media S.A., 2022.

Abstract

BackgroundOptical coherence tomography (OCT) is an important modality used in coronary intervention. However, OCT requires a high amount of contrast media, limiting its extensive application in clinical practice. This study compared OCT images of coronary lesions obtained using contrast media and very-low contrast combined Ringer's solution (VLCCR) in patients with acute coronary syndrome (ACS).MethodsThirty ACS patients with a total of 36 native lesions and stenoses from 70 to 90% were included in this study. Two kinds of flushing media (a contrast medium and VLCCR) were used in succession in a random order for OCT image pullback of each lesion. VLCCR method is using low volume contrast (4–5 ml) injected into the guiding catheter previously combination with injector infused Ringer's solution instead of pure contrast medium. The safety of procedure was evaluated by recording the patients ‘symptoms, changes of ECG, blood pressure and heart rate. OCT images were analyzed to determine the image clarity. Lumen area and diameter were also measured and the consistency between the two media was compared.ResultsOCT procedure using either contrast or VLCCR did not show any peri-procedural adverse events. There was no difference in changes of blood pressure and heart rate in both procedures, however, VLCCR procedure showed less procedure-related symptoms and ECG changes. We found that the percentage of clear image frame was equivalent between the contrast and VLCCR media (98.0 vs. 96.9%, P = 0.90). We also observed a high degree of similarity between the different lesion phenotypes of ACS for both media. There was a linear correlation of the phenotypes obtained with these two different methods, and a significant correlation was observed between measurements obtained with contrast and VLCCR without correction for the refractive index of VLCCR (correlation coefficients ranged between 0.829 and 0.948).ConclusionsOCT imaging using VLCCR for blood clearance is feasible and safe and provides similar imaging quality compared to OCT imaging obtained using radiographic contrast media for ACS patients.

Details

Language :
English
ISSN :
2297055X
Volume :
9
Database :
Directory of Open Access Journals
Journal :
Frontiers in Cardiovascular Medicine
Publication Type :
Academic Journal
Accession number :
edsdoj.74cbd2a8c5db4aa187b3371d0e2bf005
Document Type :
article
Full Text :
https://doi.org/10.3389/fcvm.2022.844114