Time-of-use (TOU) electricity rate for vehicle-to-grid (V2G) to minimize a charging station capacity
- Source :
- International Journal of Electrical Power & Energy Systems, Vol 161, Iss , Pp 110209- (2024)
- Publication Year :
- 2024
- Publisher :
- Elsevier, 2024.
-
Abstract
- This paper introduces a framework to yield an electricity rate for vehicle-to-grid (V2G) charging station (CS) to minimize installation capacity of a charging station considering electric vehicle (EV) arrival/departure time distribution. Two different layers are designed to avoid an obstacle encountered when formulating the problem as a convex optimization and to represent an EV aggregator and an electricity rate decision maker – a regulator. The EV aggregator layer focuses on increasing the profit and the regulator minimizes the peak load of the V2G CS. Linear programming was formulated for the former layer, and a modified particle swarm optimization (PSO) method was developed for the latter. Modification of the PSO approach allowed for easier escape of local minima, resulting in a new electricity rate for the V2G CS based on the EV arrival/departure time distribution data. The algorithm employs new matrices devised in this paper to accommodate EV information in the optimization process. In a simulation study, two distinct CSs with V2G operations were evaluated, each with a different EV arrival/departure time distribution. The simulation revealed that the peak load and the profit of the aggregator vary dramatically depending on the arrival/departure time distributions.
Details
- Language :
- English
- ISSN :
- 01420615
- Volume :
- 161
- Issue :
- 110209-
- Database :
- Directory of Open Access Journals
- Journal :
- International Journal of Electrical Power & Energy Systems
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.74a317c1d4584615b904f50888530ce2
- Document Type :
- article
- Full Text :
- https://doi.org/10.1016/j.ijepes.2024.110209