Back to Search Start Over

Comparison of Six Immunoassays for Assaying Levels of Immunoglobulin G against the Nucleocapsid and Spike Proteins of SARS-CoV-2

Authors :
Itsumi Suda
Takao Kimura
Takahiko Niwa
Katsuhiko Tsunekawa
Osamu Araki
Kunio Yanagisawa
Yutaka Tokue
Masami Murakami
Source :
Journal of Clinical and Diagnostic Research, Vol 16, Iss 7, Pp DC18-DC21 (2022)
Publication Year :
2022
Publisher :
JCDR Research and Publications Private Limited, 2022.

Abstract

Introduction: Assay kits for detection of Immunoglobulin G (IgG) against the nucleocapsid protein (anti-nucleocapsid IgG) and spike proteins (anti-spike IgG) of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) were commercially provided by several manufacturers. These assay kits should be verified by measuring the same sample. Aim: To compare the diagnostic value of three Coronavirus Disease-2019 (COVID-19) kits in evaluating six immunoassays developed by three manufacturers (Abbott, Euglena, and Roche) to detect anti-nucleocapsid IgG and anti-spike IgG. Materials and Methods: The present study was an observational cross-sectional study conducted from June 2020 to December 2020. Antibody titers for anti-nucleocapsid IgG and anti-spike IgG among 429 Healthcare Workers (HCWs) in a Tone Central Hospital, Japan where a nosocomial infection of the COVID-19 occurred were measured by six immunoassays with kits developed by three different manufacturers. The sensitivity and specificity of each kit was compared to real-time Reverse Transcription-Polymerase Chain Reaction (RT-qPCR). Results: Six of the HCWs tested positive for SARS-CoV-2 via RT-qPCR, and the rest tested negative. The severity of COVID-19 among these six HCWs ranged from mild to moderate. The sensitivity and specificity values against RT-qPCR were, 100% and 99.5% for Abbott, 83.3% and 100% for Euglena, and 100% and 100% for Roche when using the nucleocapsid protein assay and 100% and 99.8% for Abbott, 100% and 100% for Euglena, and 100% and 100% for Roche when using the spike protein assay kit. Conclusion: The commercial kits provided by three manufacturers reflected the immune status of individuals. There were no major differences in the performance of these test kits. Discordant results with the antibody titer for anti-nucleocapsid IgG and anti-spike IgG were detected by using assay kits provided by Abbott and Euglena. To evaluate the past history of COVID-19, it should be noted that the single measurement of anit-nucleocapsid IgG or anti-spike IgG could not exclude false negative or positives.

Details

Language :
English
ISSN :
2249782X and 0973709X
Volume :
16
Issue :
7
Database :
Directory of Open Access Journals
Journal :
Journal of Clinical and Diagnostic Research
Publication Type :
Academic Journal
Accession number :
edsdoj.71b4a79c8f2b4f59b48d4d8a245f0ca9
Document Type :
article
Full Text :
https://doi.org/10.7860/JCDR/2022/56323.16644