Back to Search Start Over

Cement Leakage into the Posterior Spinal Canal during Balloon Kyphoplasty: A Case Report

Authors :
S Becker
J Meissner
A Tuschel
A Chavanne
M Ogon
Source :
Journal of Orthopaedic Surgery, Vol 15 (2007)
Publication Year :
2007
Publisher :
SAGE Publishing, 2007.

Abstract

We report a case of cement leakage into the posterior spinal canal due to inadvertent pedicle perforation during balloon kyphoplasty. The leakage was corrected immediately without any sequelae. Features seen on radiography and the minimally invasive procedure used for removal are described. The postoperative radiographs of 100 consecutive patients treated with balloon kyphoplasty were subsequently reviewed. Only one patient had a similar leakage but had no neurological complications.

Subjects

Subjects :
Orthopedic surgery
RD701-811

Details

Language :
English
ISSN :
23094990
Volume :
15
Database :
Directory of Open Access Journals
Journal :
Journal of Orthopaedic Surgery
Publication Type :
Academic Journal
Accession number :
edsdoj.6f5b1af391be4258a81bee36da9d3b38
Document Type :
article
Full Text :
https://doi.org/10.1177/230949900701500220