Back to Search Start Over

Evaluation of Remote Sensing-Based Evapotranspiration Datasets for Improving Hydrological Model Simulation in Humid Region of East China

Authors :
Suli Pan
Yue-Ping Xu
Haiting Gu
Bai Yu
Weidong Xuan
Source :
Remote Sensing, Vol 14, Iss 18, p 4546 (2022)
Publication Year :
2022
Publisher :
MDPI AG, 2022.

Abstract

Conventional calibration methods used in hydrological modelling are based on runoff observations at the basin outlet. However, calibration with only runoff often produces reasonable runoff but poor results for other hydrological variables. Multi-variable calibration with both runoff and remote sensing-based evapotranspiration (ET) is developed naturally, due to the importance of ET and its data availability. This study compares two main calibration schemes: (1) calibration with only runoff (Scheme I) and (2) multi-variable calibration with both runoff and remote sensing-based ET (Scheme II). ET data are obtained from three remote sensing-based ET datasets, namely Penman–Monteith–Leuning (PML), FLUXCOM, and the Global Land Evaporation Amsterdam Model (GLEAM). The aforementioned calibration schemes are applied to calibrate the parameters of the Distributed Hydrology Soil Vegetation Model (DHSVM) through ε-dominance non-dominated sorted genetic algorithm II (ε-NSGAII). The results show that all three ET datasets have good performance for areal ET in the study area. The DHSVM model calibrated based on Scheme I produces acceptable performance in runoff simulation (Kling–Gupta Efficiency, KGE = 0.87), but not for ET simulation (KGE < 0.7). However, reasonable simulations can be achieved for both variables based on Scheme II. The KGE value of runoff simulation can reach 0.87(0.91), 0.72(0.85), and 0.75(0.86) in the calibration (validation) period based on Scheme II (PML), Scheme II (FLUXCOM), and Scheme II (GLEAM), respectively. Simultaneously, ET simulations are greatly improved both in the calibration and validation periods. Furthermore, incorporating ET data into all three Scheme II variants is able to improve the performance of extreme flow simulations (including extreme low flow and high flow). Based on the improvement of the three datasets in extreme flow simulations, PML can be utilized for multi-variable calibration in drought forecasting, and FLUXCOM and GLEAM are good choices for flood forecasting.

Details

Language :
English
ISSN :
20724292 and 92340709
Volume :
14
Issue :
18
Database :
Directory of Open Access Journals
Journal :
Remote Sensing
Publication Type :
Academic Journal
Accession number :
edsdoj.6de7d730b92340709c871f3f7f35c423
Document Type :
article
Full Text :
https://doi.org/10.3390/rs14184546