Back to Search Start Over

Assessment of resection margins during breast-conserving surgery using multimodal optical coherence tomography

Authors :
D. A. Vorontsov
E. V. Gubarkova
M. A. Sirotkina
A. A. Sovetskiy
S. N. Aleksakhina
T. T. Tabagua
E. A. Busko
E. N. Imyanitov
S. S. Kuznetsov
A. Yu. Vorontsov
E. V. Zagaynova
S. V. Gamayunov
V. Yu. Zaytsev
P. V. Krivorotko
N. D. Gladkova
Source :
Опухоли женской репродуктивной системы, Vol 19, Iss 2, Pp 34-46 (2023)
Publication Year :
2023
Publisher :
ABV-press, 2023.

Abstract

Background. Breast cancer (BC) has been ranked first in morbidity and mortality among the female population in Russian Federation for several years. Rapid and accurate intraoperative examination of the cleanliness of resection margins is the main condition for breast-conserving surgery (BCS) to reduce the risks of local recurrence.Aim. To examine the tumor margins and assess the cleanliness of the resection margins in BCS in patients diagnosed with BC using multimodal optical coherence tomography (MM OCT) with comparative planned histological and additional molecular genetic analysis.Materials and methods. The study was carried out on postoperative samples of tumor and non-tumor breast tissue obtained from 115 patients with BC T1–2N0M0G2–3 stage IA–IIA, after BCS in the volume of radical resection or lumpectomy with histological control of the resection margins. A spectral domain MM OCT device (OCT 1300-E, BioMedTech LLC, Russia) was used, which provides structural OCT images to study the backscattering properties of tissue and allows performing a quantitative assessment of the elastic properties of the tissue by compression optical coherence elastography (OCE).Results. The MM OCT method was able to determine the exact margins between the tumor and non-tumor breast tissue. The main signs of the tumor were a decrease in the level and depth of penetration of the OCT signal in the structural OCT images, as well as an increase in the stiffness values (>200 kPa) in the OCE images with the highest stiffness values (>600 kPa) in the area of tumor cell accumulations. The use of compression OCE made it possible to detect clusters of tumor cells in the margins of resection at a distance of 5 mm from the visible border of the tumor. Among the 132 studied resection margins in 6 cases, the positive resection margin was determined by the OCE method, which was subsequently confirmed histologically. The negative resection margins were characterized by the lowest stiffness values (

Details

Language :
Russian
ISSN :
19944098 and 19998627
Volume :
19
Issue :
2
Database :
Directory of Open Access Journals
Journal :
Опухоли женской репродуктивной системы
Publication Type :
Academic Journal
Accession number :
edsdoj.6d899408e46f383ab6027f8d369af
Document Type :
article
Full Text :
https://doi.org/10.17650/1994-4098-2023-19-2-34-46