Back to Search Start Over

Research on the Application Value of 18F-FDG PET/CT Combined with Neuronal Antibody Detection in the Diagnosis and Treatment of PNS Patients

Authors :
Leilei YUAN
Qian CHEN
Zhen QIAO
Xiaotong LI
Di FAN
Wei ZHANG
Lin AI
Source :
CT Lilun yu yingyong yanjiu, Vol 32, Iss 2, Pp 209-215 (2023)
Publication Year :
2023
Publisher :
Editorial Office of Computerized Tomography Theory and Application, 2023.

Abstract

Objective: To explore the clinical value of whole-body 18F-FDG PET/CT combined with neuroantibody detection in the diagnosis and treatment of paraneoplastic neurological syndromes (PNS). Methods: Clinical, laboratory, and imaging data of 56 hospitalized patients with suspected PNS who underwent systemic 18F-FDG PET/CT and neuropathic tumor antibody detection were retrospectively collected and followed-up on. ROC curve analysis was performed to compare the diagnostic efficacy of PET/CT, neuronal antibodies, and their combined detection results. Results: Among the 56 patients with suspected PNS, there were 20 with malignant tumors, including 19 cases complicated with PNS and 1 patient with spinal cord metastasis which also le d to neurological symptoms. 18F-FDG PET/CT imaging indicated tumors or possible tumors in 23 cases, of which 20 cases were true positive, 3 cases were false positive (the follow-up results were reflux esophagitis, reactive bone changes, or inflammatory lesions in the neck), and the remaining 33 cases were true negative. The sensitivity, specificity, and accuracy of PET/CT were 100%, 91.7%, and 94.6%, respectively. There were 33 cases with positive neuroantibodies, including 8 cases of tumors with PNS (3 cases with anti-amphiphysin antibody encephalitis, 2 cases with anti-GABAb antibody encephalitis, 1 case with anti-Yo antibody encephalitis, and 2 cases with anti-Hu antibody encephalitis). Moreover, there were 25 cases without tumors (10 cases with LGI1 antibody encephalitis, 3 cases with anti-amphiphysin antibody encephalitis, 1 case with anti-Hu antibody encephalitis, 3 cases with anti-GABAb antibody encephalitis, 3 cases with anti-Yo antibody encephalitis, 1 case with Anti-caspr2, 1 case with GAD65, 1 case with NMDA, 1 case with PNMA, and 1 case with SOX1 antibody (1 case each). Of these, 23 cases were negative (12 cases with tumor). The sensitivity, specificity, and accuracy of the neuronal antibody test were 40.0%, 30.6%, and 33.9%, respectively. Furthermore, the sensitivity, specificity, and accuracy of the combined detection were 100.0%, 33.3%, 57.1%, 50%, 94.4%, and 78.6%, respectively. ROC analysis showed that the AUC was 0.958 (P=0.0000.05; 95% CI 0.199~0.506), 0.667 (P=0.040

Details

Language :
English, Chinese
ISSN :
10044140
Volume :
32
Issue :
2
Database :
Directory of Open Access Journals
Journal :
CT Lilun yu yingyong yanjiu
Publication Type :
Academic Journal
Accession number :
edsdoj.6b4317027910409c98edc88b34c051c1
Document Type :
article
Full Text :
https://doi.org/10.15953/j.ctta.2022.070