Back to Search Start Over

Development of a Novel Intraoperative Neuromonitoring System Using an Accelerometer Sensor in Thyroid Surgery: A Porcine Model Study

Authors :
Eui-Suk Sung
Jin-Choon Lee
Sung-Chan Shin
Hyun-Keun Kwon
Han-Seul Na
Da-Hee Park
Seong-Wook Choi
Jung-Hoon Ro
Byung-Joo Lee
Source :
Clinical and Experimental Otorhinolaryngology, Vol 12, Iss 4, Pp 420-426 (2019)
Publication Year :
2019
Publisher :
Korean Society of Otorhinolaryngology-Head and Neck Surgery, 2019.

Abstract

Objectives. The sensitivity and positive predictive value of widely used intraoperative neuromonitoring (IONM) using electromyography (EMG) of the vocalis muscle in thyroid surgery are controversial. Thus, we developed a novel IONM system with an accelerometer sensor that uses the piezoelectric effect instead of EMG to detect laryngeal twitching. The objective of this study was to evaluate the feasibility and safety of this novel IONM system during thyroid surgery in a porcine model. Methods. We developed an accelerometer sensor that uses the piezoelectric effect to measure laryngeal twitching in three dimensions. This novel accelerometer sensor was placed in the anterior neck skin (transcutaneous) or postcricoid area. Stimulus thresholds, amplitude, and latency of laryngeal twitching measured using the accelerometer sensor were compared to those measured through EMG of the vocalis muscle. Results. The amplitudes of the accelerometer sensor at the anterior neck and postcricoid area were significantly lower than those of EMG because of differences in the measurement method used to evaluate laryngeal movement. However, no significant differences in stimulus thresholds between the EMG endotracheal tube and transcutaneous or postcricoid accelerometer sensors were observed. Conclusion. Accelerometer sensors located at the anterior neck or postcricoid area were able to identify laryngeal twitching. The stimulus intensity measured with these sensors was equivalent to that from conventional vocalis EMG. Our novel IONM system with an accelerometer sensor that checks changes in surface acceleration can be an alternative to EMG of the vocalis muscle for IONM in the future.

Details

Language :
English
ISSN :
19768710 and 20050720
Volume :
12
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Clinical and Experimental Otorhinolaryngology
Publication Type :
Academic Journal
Accession number :
edsdoj.6ab5888abaa45188a51332a60dd2bd4
Document Type :
article
Full Text :
https://doi.org/10.21053/ceo.2019.00423