Abstract

Objective. To compare the thickness of corneal layers, specifically the Descemet’s membrane (DM), in normal corneas and in failed grafts due to rejection (FGRs) using the digital histopathology and to propose a model for the measurement of corneal layers using this method. Methods. This is a prospective, cross-sectional study performed at the MUHC-McGill University Ocular Pathology & Translational Research Laboratory (McGill University, Montreal, Canada). Histopathological sections of 25 normal human corneas and 40 FGRs were fully digitalized and examined. Inclusion criteria: samples diagnosed as normal corneas or FGRs, from patients older than 18 years of age. Exclusion criteria: histopathological sections without adequate tissue or missing epidemiological information. For each sample, the thicknesses of the epithelium, stroma, and DM were acquired. From a perpendicular plane of reference, two central measurements and two nasal and two temporal peripheral measurements were obtained. Results. There were differences between the normal and FGR groups in the mean central thickness of the epithelium (p

Subjects

Subjects :
Ophthalmology
RE1-994

Details

Language :
English
ISSN :
2090004X and 20900058
Volume :
2019
Database :
Directory of Open Access Journals
Journal :
Journal of Ophthalmology
Publication Type :
Academic Journal
Accession number :
edsdoj.6a9aaf02b5af41a8925518c96b00bac3
Document Type :
article
Full Text :
https://doi.org/10.1155/2019/8283175