Back to Search Start Over

Comparative assessment of digital pathology systems for primary diagnosis

Authors :
Sathyanarayanan Rajaganesan
Rajiv Kumar
Vidya Rao
Trupti Pai
Neha Mittal
Ayushi Sahay
Santosh Menon
Sangeeta Desai
Source :
Journal of Pathology Informatics, Vol 12, Iss 1, Pp 25-25 (2021)
Publication Year :
2021
Publisher :
Elsevier, 2021.

Abstract

Background: Despite increasing interest in whole-slide imaging (WSI) over optical microscopy (OM), limited information on comparative assessment of various digital pathology systems (DPSs) is available. Materials and Methods: A comprehensive evaluation was undertaken to investigate the technical performance–assessment and diagnostic accuracy of four DPSs with an objective to establish the noninferiority of WSI over OM and find out the best possible DPS for clinical workflow. Results: A total of 2376 digital images, 15,775 image reads (OM - 3171 + WSI - 12,404), and 6100 diagnostic reads (OM - 1245, WSI - 4855) were generated across four DPSs (coded as DPS: 1, 2, 3, and 4) using a total 240 cases (604 slides). Onsite technical evaluation revealed successful scan rate: DPS3 < DPS2 < DPS4 < DPS1; mean scanning time: DPS4 < DPS1 < DPS2 < DPS3; and average storage space: DPS3 < DPS2 < DPS1 < DPS4. Overall diagnostic accuracy, when compared with the reference standard for OM and WSI, was 95.44% (including 2.48% minor and 2.08% major discordances) and 93.32% (including 4.28% minor and 2.4% major discordances), respectively. The difference between the clinically significant discordances by WSI versus OM was 0.32%. Major discordances were observed mostly using DPS4 and least in DPS1; however, the difference was statistically insignificant. Almost perfect (κ ≥ 0.8)/substantial (κ = 0.6–0.8) inter/intra-observer agreement between WSI and OM was observed for all specimen types, except cytology. Overall image quality was best for DPS1 followed by DPS4. Mean digital artifact rate was 6.8% (163/2376 digital images) and maximum artifacts were noted in DPS2 (n = 77) followed by DPS3 (n = 36). Most pathologists preferred viewing software of DPS1 and DPS2. Conclusion: WSI was noninferior to OM for all specimen types, except for cytology. Each DPS has its own pros and cons; however, DPS1 closely emulated the real-world clinical environment. This evaluation is intended to provide a roadmap to pathologists for the selection of the appropriate DPSs while adopting WSI.

Details

Language :
English
ISSN :
21533539
Volume :
12
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Pathology Informatics
Publication Type :
Academic Journal
Accession number :
edsdoj.687c30e7384c4cad8fb23bfcf5257fd3
Document Type :
article
Full Text :
https://doi.org/10.4103/jpi.jpi_94_20