Back to Search Start Over

Pre-procedure 18F-FDG PET/CT imaging improves the performance of CT-guided transthoracic biopsy

Authors :
Ai-Fang Jin
Zhe-Huang Luo
Wan-Ling Qi
Qian Liu
Source :
Diagnostic and Interventional Radiology, Vol 30, Iss 6, Pp 380-384 (2024)
Publication Year :
2024
Publisher :
Galenos Publishing House, 2024.

Abstract

PURPOSE: To compare computed tomography (CT)-guided transthoracic lung biopsies (CTLB) with and without pre-procedure 18F-fludeoxyglucose positron emission tomography (18F-FDG PET)/CT images in the diagnosis of pulmonary nodules/masses. METHODS: This is a case-control study in a single center. The data of patients with a transthoracic lung biopsy guided by CT and pre-procedure 18F-FDG PET/CT (group 2, here called the “PETCTLB” group), including demographics, clinical characteristics, and biopsy-related parameters, were collected. The PET/CT scan was performed within 15 days before the biopsy. The data from patients with CTLB were used as controls (group 1). Biopsies for all patients were performed by the same physician between January 2019 and December 2021. The final diagnosis was based on surgical outcomes, or imaging findings, and the results of at least one 6-month follow-up. The demographics and clinical characteristics of patients, lesions and biopsy-related variables, diagnostic yields, and incidence of complications were compared between the two groups. Two-tailed t-tests were used to compare the mean values in the two independent groups, while categorical variables were compared using the Pearson chi-squared test, and P values < 0.05 were considered to be significant. RESULTS: A total of 84 patients were included, and 84 biopsies of 84 lung nodules/masses were analyzed. The demographics and clinical characteristics of group 2 (n = 39; 21 men; mean age, 63.2 ± 9.29 years) and group 1 (n = 45; 30 men; mean age, 61.2 ± 12.3 years) had no significant difference (P = 0.230 and 0.397, respectively). The procedure duration (11.1 ± 3.0 vs. 12.9 ± 3.3 minutes, P = 0.008), the number of samples (2.6 ± 0.5 vs. 3.1 ± 0.4, P < 0.001), diagnostic accuracy (97.4% vs. 82.2%, P = 0.033), and bleeding complication (25.6% vs. 42.2%, P = 0.034) of group 2 and group 1 were statistically different. CONCLUSION: A biopsy guided by CT plus pre-procedure 18F-FDG PET/CT (PETCTLB) is a safe procedure that can provide a precise diagnosis in the majority of lung nodules/masses. It has better diagnostic performance than CTLB.

Details

Language :
English
ISSN :
13053825 and 13053612
Volume :
30
Issue :
6
Database :
Directory of Open Access Journals
Journal :
Diagnostic and Interventional Radiology
Publication Type :
Academic Journal
Accession number :
edsdoj.66c5a37232a04ad3b102b8bcd9047f1e
Document Type :
article
Full Text :
https://doi.org/10.4274/dir.2023.232364