Back to Search Start Over

Efeitos da anemia materna na cardiotocografia computadorizada e perfil biofísico fetal Effects of maternal anemia on computerized cardiotocography and fetal biophysical profile

Authors :
Roseli Mieko Yamamoto Nomura
Marina Caldana Gordon
Giancarlo Fatobene
Ana Maria Kondo Igai
Marcelo Zugaib
Source :
Revista Brasileira de Ginecologia e Obstetrícia, Vol 31, Iss 12, Pp 615-620 (2009)
Publication Year :
2009
Publisher :
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, 2009.

Abstract

OBJETIVOS: avaliar a influência dos níveis de hemoglobina (Hb) materna nos padrões da frequência cardíaca fetal (FCF) e no perfil biofísico fetal (PBF) em gestações a termo. MÉTODOS: gestantes portadoras de anemia (Hb11,0 g/dL). Foram excluídos casos com anomalias ou restrição do crescimento fetal. A avaliação da FCF foi realizada pela cardiotocografia computadorizada (Sistema8002-Sonicaid) e análise do traçado com 30 minutos de exame. O PBF foi realizado em todas as pacientes. Foram utilizados os testes t de Student, teste do χ2 e teste exato de Fisher. O nível de significância utilizado foi de 0,05. RESULTADOS: A média da Hb materna no grupo com anemia (n=18) foi de 9,4 g/dL (DP=1,4 g/dL) e no Grupo Controle 12,4 g/dL (DP=1,3 g/dL). Quanto aos parâmetros da cardiotocografia, não foi constatada diferença significativa nas médias entre os grupos com anemia e controle, respectivamente: FCF basal (131,3 bpm versus 133,7 bpm, p=0,5), acelerações da FCF > 10 bpm (7,9 versus. 8,2, p=0,866), acelerações da FCF > 15 bpm (5,2 versus 5,4, p=0,9), episódios de alta variação da FCF (17,1 versus 15,5 min, p=0,5), episódios de baixa variação da FCF (4,4 versus 3,6 min, p=0,6), e variação de curto prazo (10,5 versus 10,9 ms, p=0,5). Em ambos os grupos, todas as pacientes apresentaram PBF normal. CONCLUSÕES: este estudo sugere que a anemia materna leve ou moderada, sem outras comorbidades maternas ou fetais, não se associa a anormalidades nos parâmetros do perfil biofísico fetal e da FCF analisada pela cardiotocografia computadorizada.PURPOSES: to evaluate the influence of maternal hemoglobin (Hb) levels in the patterns of fetal heart rate (FHR) and in the fetal biophysical profile (FBP) in term gestations. METHODS: pregnant women with anemia (Hb11,0 g/dL). Cases of anomalies or fetal growing restrictions were excluded. The FHR evaluation was performed by computerized cardiotocography (8002 System-Sonicaid), and by record analysis during 30 minutes of exam. The FBP was done in all the patients. Student's, χ2 and Fisher's exact tests were used, with 0.05 significance level. RESULTS: The average of maternal Hb in the group with anemia (n=18) was 9.4 g/dL (DP=1.4 g/dL), and in the control group, 12.4g/dL (DP=1.3 g/dL). There has been no significant mean differences between groups concerning the cardiotocography parameters, respectively: basal FHR(131.3 versus 133.7 bpm, p=0.5), FHR accelerations > 10b pm (7.9 versus 8.2, p=0.866), FHR accelerations > 15 bpm (5.2 versus. 5.4, p=0.9), episodes of high variation of the FHR (17.1 versus 15.5 min, p=0,5), episodes of variation of the FHR (4.4 versus 3.6 min, p=06), and short term variation (10.5 versus 10.9 ms, p=0.5). In both groups, all patients presented normal FBP. CONCLUSIONS: this study suggests that light or moderate maternal anemia, without other maternal or fetal comorbidity, is not associated with abnormalities in the parameters of fetal biophysical profile and of the FHR analyzed by computerized cardiotocography.

Details

Language :
English, Portuguese
ISSN :
01007203
Volume :
31
Issue :
12
Database :
Directory of Open Access Journals
Journal :
Revista Brasileira de Ginecologia e Obstetrícia
Publication Type :
Academic Journal
Accession number :
edsdoj.6638065c96db4332bf08ae702447c9e0
Document Type :
article
Full Text :
https://doi.org/10.1590/S0100-72032009001200007