Back to Search Start Over

Biomechanical Evaluation of a New Suture Button Technique for Reduction and Stabilization of the Distal Tibiofibular Syndesmosis

Authors :
Andres Eduardo O’Daly MD
R. Timothy Kreulen MD
Sorawut Thamyongkit MD
Alfred Pisano MD
Kitchai Luksameearunothai MD
Erik A. Hasenboehler MD
Melvin D. Helgeson MD
Babar Shafiq MD, MSPT
Source :
Foot & Ankle Orthopaedics, Vol 5 (2020)
Publication Year :
2020
Publisher :
SAGE Publishing, 2020.

Abstract

Background: Stabilization methods for distal tibiofibular syndesmotic injuries present risk of malreduction. We compared reduction accuracy and biomechanical properties of a new syndesmotic reduction and stabilization technique using 2 suture buttons placed through a sagittal tunnel in the fibula and across the tibia just proximal to the incisura with those of the conventional method. Methods: Syndesmotic injury was created in 18 fresh-frozen cadaveric lower leg specimens. Nine ankles were repaired with the conventional method and 9 with the new technique. Reduction for the conventional method was performed using thumb pressure under direct visualization and for the new method by tightening both suture buttons passed through the fibular and tibial tunnels. Computed tomography was used to assess reduction accuracy. Torsional resistance, fibular rotation, and fibular translation were evaluated during biomechanical testing. Results: The new technique showed less lateral translation of the fibula on CT measurements after reduction (0.06 ± 0.06 mm) than the conventional method (0.26 ± 0.31 mm), P = .02. The new technique produced less fibular rotation during internal rotation after 0 cycles (new –2.4 ± 1.4 degrees; conventional –5.0 ± 1.2 degrees, P = .001), 100 cycles (new –2.1 ± 1.9 degrees; conventional –4.6 ± 1.4 degrees, P = .01), and 500 cycles (new –2.2 ± 1.6 degrees; conventional –5.3 ± 2.5 degrees, P = .01) and during external rotation after 100 cycles (new 3.9 ± 3.3 degrees; conventional 5.9 ± 3.5 degrees, P = .02) and 500 cycles (new 3.3 ± 3.2 degrees; conventional 6.3 ± 2.6 degrees, P = .03). Fixation failed in 3 specimens. Conclusion: The new syndesmotic reduction and fixation technique resulted in more accurate reduction of the fibula in the tibial incisura in the coronal plane and better rotational stability compared with the conventional method. Clinical Relevance: This new technique of syndesmosis reduction and stabilization may be a reliable alternative to current methods.

Subjects

Subjects :
Orthopedic surgery
RD701-811

Details

Language :
English
ISSN :
24730114
Volume :
5
Database :
Directory of Open Access Journals
Journal :
Foot & Ankle Orthopaedics
Publication Type :
Academic Journal
Accession number :
edsdoj.661568cde7149b5a394b2b10c68c7b8
Document Type :
article
Full Text :
https://doi.org/10.1177/2473011420969140