Back to Search Start Over

Chondrosarcoma evaluation using hematein-based x-ray staining and high-resolution 3D micro-CT: a feasibility study

Authors :
Alexandra S. Gersing
Melanie A. Kimm
Christine Bollwein
Patrick Ilg
Carolin Mogler
Felix G. Gassert
Georg C. Feuerriegel
Carolin Knebel
Klaus Woertler
Daniela Pfeiffer
Madleen Busse
Franz Pfeiffer
Source :
European Radiology Experimental, Vol 8, Iss 1, Pp 1-12 (2024)
Publication Year :
2024
Publisher :
SpringerOpen, 2024.

Abstract

Abstract Background Chondrosarcomas are rare malignant bone tumors diagnosed by analyzing radiological images and histology of tissue biopsies and evaluating features such as matrix calcification, cortical destruction, trabecular penetration, and tumor cell entrapment. Methods We retrospectively analyzed 16 cartilaginous tumor tissue samples from three patients (51-, 54-, and 70-year-old) diagnosed with a dedifferentiated chondrosarcoma at the femur, a moderately differentiated chondrosarcoma in the pelvis, and a predominantly moderately differentiated chondrosarcoma at the scapula, respectively. We combined a hematein-based x-ray staining with high-resolution three-dimensional (3D) microscopic x-ray computed tomography (micro-CT) for nondestructive 3D tumor assessment and tumor margin evaluation. Results We detected trabecular entrapment on 3D micro-CT images and followed bone destruction throughout the volume. In addition to staining cell nuclei, hematein-based staining also improved the visualization of the tumor matrix, allowing for the distinction between the tumor and the bone marrow cavity. The hematein-based staining did not interfere with further conventional histology. There was a 5.97 ± 7.17% difference between the relative tumor area measured using micro-CT and histopathology (p = 0.806) (Pearson correlation coefficient r = 0.92, p = 0.009). Signal intensity in the tumor matrix (4.85 ± 2.94) was significantly higher in the stained samples compared to the unstained counterparts (1.92 ± 0.11, p = 0.002). Conclusions Using nondestructive 3D micro-CT, the simultaneous visualization of radiological and histopathological features is feasible. Relevance statement 3D micro-CT data supports modern radiological and histopathological investigations of human bone tumor specimens. It has the potential for being an integrative part of clinical preoperative diagnostics. Key points • Matrix calcifications are a relevant diagnostic feature of bone tumors. • Micro-CT detects all clinically diagnostic relevant features of x-ray-stained chondrosarcoma. • Micro-CT has the potential to be an integrative part of clinical diagnostics. Graphical Abstract

Details

Language :
English
ISSN :
25099280
Volume :
8
Issue :
1
Database :
Directory of Open Access Journals
Journal :
European Radiology Experimental
Publication Type :
Academic Journal
Accession number :
edsdoj.654e0194151346038910d25a9456ded2
Document Type :
article
Full Text :
https://doi.org/10.1186/s41747-024-00454-0