Abstract
- The aim of this work was the development of an isolated heart setup to delineate the interactions between intraventricular flow features, hemodynamic parameters and mechano-energetics after certain mitral valve therapies. Five porcine hearts were explanted and prepared for (i) edge-to-edge mitral valve repair, (ii) implantation of a rotatable biscupid mechanical valve prosthesis. Flow structures were visualized using echocardiography while hemodynamics was recorded in terms of pressures, flow rates and ventricular volume. Hemodynamic and cardiac mechano-energetics implied a marginal effect (
Details
- Language :
- English
- ISSN :
- 23645504
- Volume :
- 6
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- Current Directions in Biomedical Engineering
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.64c2f00623914e2ba4cc52f6790c7ace
- Document Type :
- article
- Full Text :
- https://doi.org/10.1515/cdbme-2020-0028