Back to Search Start Over

The effects of laser displacement on femtosecond laser-assisted conjunctival autograft preparation for pterygium surgery.

Authors :
Valencia Hui Xian Foo
Yu-Chi Liu
Hon Shing Ong
Marcus Ang
Jodhbir S Mehta
Source :
PLoS ONE, Vol 16, Iss 1, p e0245223 (2021)
Publication Year :
2021
Publisher :
Public Library of Science (PLoS), 2021.

Abstract

AimsTo evaluate the effects of no-suction femtosecond laser (FSL) stability on conjunctival autograft (CAG) dissection in pterygium surgery.MethodsProspective analysis of 35 eyes from 34 subjects who underwent femtosecond laser-assisted pterygium surgery with the Ziemer Z8 laser (Ophthalmic Systems AG, Switzerland). Intraoperative absolute FSL displacements were measured and correlated with the duration and ease of CAG peel, CAG thickness, measured with intraoperative optical coherence tomography, and deviation from intended graft thickness.ResultsThe median absolute FSL displacement was 22 μm (interquartile range [IQR] 14.7 to 60.8), while median vertical FSL displacement was 14.7 μm (IQR 7.3 to 44) and median horizontal FSL displacement was 22.0 μm (IQR 14.7 to 44). 65.7% had a grade 1 peel, 11.4% had grade 2 peel, 14.3% had grade 3 peel and 8.6% had grade 4 peel. The median duration of CAG peel was 5.4 seconds (IQR 3 to 21.4). The median CAG thickness was 69 μm (IQR 60.3 to 78.5), and the median deviation from targeted graft thickness was 9 μm (IQR 1 to 16). Eyes with more difficult peels and longer duration of CAG peels had significantly greater vertical FSL displacements (p = 0.04 and 0.02 respectively), but not horizontal displacement, age, ethnicity, CAG thickness or deviation from original thickness, compared to those with better quality and shorter duration peels. 1 eye (2.9%) had an incomplete CAG peel with a buttonhole and 2 eyes had graft tears (5.7%).ConclusionMicro-displacements during the suction-free CAG preparation are common but they did not affect the quality of the CAG peel, duration of peel, or CAG thickness. However, vertical globe displacement during FSL-assisted CAG creation was significantly associated with a more difficult and longer CAG peel duration. This highlights the importance of the cornea traction suture fixation to ensure stability of the eye during FSL application.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
16
Issue :
1
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.61d77c87834108b5c832e80713f67a
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0245223