Back to Search Start Over

Clinical application of optic nerve sheath diameter by bedside ultrasound in the prognosis assessment of severe traumatic brain injury

Authors :
HAN Bing⁃sha
Jiao LI
Xiang LI
Yan⁃ru LI
Lei ZHANG
Jing⁃he ZHAO
Guang FENG
Source :
Chinese Journal of Contemporary Neurology and Neurosurgery, Vol 20, Iss 8, Pp 694-699 (2020)
Publication Year :
2020
Publisher :
Tianjin Huanhu Hospital, 2020.

Abstract

Objective To evaluate the clinical value of bedside ultrasound measurement of optic nervesheath diameter (ONSD) in the prognosis of severe traumatic brainin jury (sTBI). Methods Atotal of 78 sTBI patients admitted to Department of Neurosurgery ICU of He'nan Provincial People's Hospital from April 2017 to April 2019 were enrolled. Intracranial pressure (ICP) monitoring probe was placed when the patient was admitted, and bedside ultrasound was used to detect the ONSD. The values of ONSD in supine position and 30° head⁃up position, 30min before and after ventilation, and 30min before and after mannitol treatment were observed and analyzed. Receiver operating characteristic curve (ROC) was used to analyze the predictive value of ONSD for unfavourable prognosis of sTBI patients. Results The mean ICP in unfavourable prognosis group [Glasgow Outcome Scale (GOS) score 1-3] was higher than that in favourable prognosis group (GOS score 4-5; t=2.111, P=0.038). After 30° head⁃up position, 30 min after ventilation and mannitol treatment, the values of ONSD were lower than supine position (F=6.644, P= 0.012),and30 min befor eventilation (F=4.492, P=0.037) and mannitol treatment (F=5.552, P=0.021), and ONSD in unfavourable prognosis group were higher than those in favourable prognosis group (posture change: F=16.751, P=0.000; ventilation treatment: F=29.776, P=0.000; application of mannitol: F= 12.465, P=0.002). There was a positive correlation between ONSD and ICP (r=0.691, P=0.000). ONSD at 5.53 mm was the optimal threshold for unfavourable prognosis, the area under the curve (AUC) was 0.776 (95%CI: 0.826-0.978, P =0.000). The sensitivity was 91.52% and the specificity was 87.14%. Conclusions Dynamic detection of ONSD by bedside ultrasound is helpful to evaluate the prognosis of sTBI, and guide the precise treatment of severe ICP. DOI:10.3969/j.issn.1672⁃6731.2020.08.006

Details

Language :
English, Chinese
ISSN :
16726731
Volume :
20
Issue :
8
Database :
Directory of Open Access Journals
Journal :
Chinese Journal of Contemporary Neurology and Neurosurgery
Publication Type :
Academic Journal
Accession number :
edsdoj.5c2ce03af0bd4eaaa32df2e26e680080
Document Type :
article