Back to Search Start Over

Standard digit-based versus 90° rotation technique for supraglottic airway device insertion: a meta-analysis of randomized controlled trials

Authors :
Chang-Hoon Koo
Ah-Young Oh
Young-Tae Jeon
Jung-Won Hwang
Jung-Hee Ryu
Source :
Korean Journal of Anesthesiology, Vol 75, Iss 3, Pp 266-275 (2022)
Publication Year :
2022
Publisher :
Korean Society of Anesthesiologists, 2022.

Abstract

Background Prompt insertion and placement of supraglottic airway (SGA) devices in the correct position are required to secure the airway. This meta-analysis was performed to validate the usefulness of the 90° rotation technique as compared with the standard digit-based technique for the insertion of SGA devices in anesthetized patients in terms of insertion success rate, insertion time, and postoperative complications. Methods A literature search of PubMed, EMBASE, CENTRAL, CINAHL, Scopus, and Web of Science was conducted. Randomized controlled trials, without limitations on publication period, language, journal, or region, until July 2021, that compared the 90° rotation and the standard digit-based techniques for insertion of SGA devices in anesthetized patients were included. Results The first-attempt (risk ratio [RR]: 1.16, 95% CI [1.09, 1.25], P < 0.001) and overall success rates (RR: 1.06, 95% CI [1.03, 1.09], P < 0.001) were significantly higher in the 90° rotation group. The insertion time was shorter in the 90° rotation group (mean difference: −4.42 s, 95% CI [−6.70, −2.15 s], P < 0.001). The incidences of postoperative sore throat (RR: 0.63, 95% CI [0.49, 0.83], P < 0.001) and blood staining (RR: 0.28, 95% CI [0.20, 0.39], P < 0.001) were lower in the 90° rotation group. Conclusions The use of the 90° rotation technique increases the success rate of SGA device insertion and decreases postoperative complications as compared with that of the standard digit-based technique in anesthetized patients.

Details

Language :
English
ISSN :
20056419 and 20057563
Volume :
75
Issue :
3
Database :
Directory of Open Access Journals
Journal :
Korean Journal of Anesthesiology
Publication Type :
Academic Journal
Accession number :
edsdoj.5b1aacefa8d44c78bae53d323cd7dfa5
Document Type :
article
Full Text :
https://doi.org/10.4097/kja.21441