Back to Search Start Over

Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes

Authors :
Camila Buziquia Dartibale
Nelson Shozo Uchimura
Luiz Nery
Angelita Polato Schumeish
Liza Yurie Teruya Uchimura
Rosangela Getirana Santana
Taqueco Teruya Uchimura
Source :
Revista Brasileira de Ginecologia e Obstetrícia, Vol 39, Iss 7, Pp 317-321 (2017)
Publication Year :
2017
Publisher :
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, 2017.

Abstract

Abstract Purpose This study aimed to evaluate and validate the qualitative human chorionic gonadotropin β subunit (β-hCG) test of the vaginal fluid washings of pregnant women with premature rupture of fetal membranes (PROM). Methods Cross-sectional study of pregnant women between gestational weeks 24 and 39 who underwent consultations in one of our institutions. They were divided into two groups: group A (pregnant women clinically diagnosed with PROM) and group B (pregnant women without loss of amniotic liquid). The patients were subjected to a vaginal fluid washing with 3 mL of saline solution, which was aspirated subsequently with the same syringe. The solution was immediately sent to the laboratory to perform the vaginal β-hCG test with cut-off points of 10 mIU/mL (β-hCG-10) and/or 25 mIU/mL (β-hCG-25). Results The β-hCG-10 test of the vaginal secretion was performed in 128 cases. The chi-squared test with Yates’ correction showed a statistically significant difference between the 2 groups (p = 0.0225). The sensibility, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy parameters were 77.1%, 43.6%, 52.3%; 70.4%; and 58.6% respectively. The β-hCG-25 test of the vaginal washing was performed in 49 cases. The analysis by Fisher’s exact test showed a statistically significant difference between the groups (p = 0.0175). The sensibility, specificity, PPV, NPV, and accuracy parameters were 44.4%, 87.1%, 66.6%; 72.9%; and 71.4% respectively. Conclusions The β-hCG-25 test showed better accuracy for the diagnosis of PROM, and can corroborate the early diagnosis of PROM because it is a simple and quick exam.

Details

Language :
English, Portuguese
ISSN :
01007203
Volume :
39
Issue :
7
Database :
Directory of Open Access Journals
Journal :
Revista Brasileira de Ginecologia e Obstetrícia
Publication Type :
Academic Journal
Accession number :
edsdoj.5ac981cf5774440b83470f12f0389ed1
Document Type :
article
Full Text :
https://doi.org/10.1055/s-0037-1603939