Back to Search Start Over

Establishment of ISO 4037-1 X-ray narrow-spectrum series

Authors :
Deliang Zhang
Wanchang Lai
Jinjie Wu
Haiyan Du
Rui Zhao
Song Fan
Source :
The Journal of Engineering (2019)
Publication Year :
2019
Publisher :
Wiley, 2019.

Abstract

In order to calibrate radiation protection instruments and determine radiation dose, it is critical to establish an X-ray narrow-spectrum series recommended by the standard ISO 4037-1 which is published by the International Standardisation Organisation (ISO). By experiment, the qualities of filtered X radiation of narrow-spectrum series in the range from 60 to 300 kV were established. The differences of the first half-value layer (HVL1) and the second HVL (HVL2) between experimental results and the values given in the standard ISO 4037-1 were all within 5%. What is more, the Monte Carlo code EGSnrc was used to simulate the spectra of these radiation qualities, which showed a good agreement with these spectra given in the standard ISO 4037-1. The spectral resolution, mean energy and effective energy of these reference qualities can be obtained, which are all have good agreement with the given values.

Details

Language :
English
ISSN :
20513305
Database :
Directory of Open Access Journals
Journal :
The Journal of Engineering
Publication Type :
Academic Journal
Accession number :
edsdoj.5a68d5a1054c4118842c0fdec7b4eb78
Document Type :
article
Full Text :
https://doi.org/10.1049/joe.2018.9126