Back to Search Start Over

The advantages of femtosecond laser-assisted cataract surgery for zonulopathy

Authors :
Teshigawara T
Meguro A
Sanjo S
Hata S
Mizuki N
Source :
International Medical Case Reports Journal, Vol Volume 12, Pp 109-116 (2019)
Publication Year :
2019
Publisher :
Dove Medical Press, 2019.

Abstract

Takeshi Teshigawara,1–3 Akira Meguro,3 Sanae Sanjo,1 Seiichiro Hata,4 Nobuhisa Mizuki31Department of Ophthalmology, Yokosuka Chuoh Eye Clinic, Yokosuka, Kanagawa, Japan; 2Department of Ophthalmology, Tsurumi Chuoh Eye Clinic, Yokohama, Kanagawa, Japan; 3Department of Ophthalmology, Yokohama City University School of Medicine, Yokohama, Kanagawa, Japan; 4Department of Ophthalmology, Yokohama Sky Eye Clinic, Yokohama, Kanagawa, JapanAbstract: Zonulopathy is a major concern if found during cataract surgery as it can cause further complications. Such complications may occur during continuous curvilinear capsulorhexis (CCC), lens fragmentation and intraocular lens (IOL) implantation. Femtosecond laser-assisted cataract surgery (FLACS) devices, such as the LenSX (Alcon Laboratories) are advantageous because they can detect the area and largest point of zonulopathy via anterior segment optical coherent tomography (AS-OCT) before the manual part of the procedure. CCC and lens fragmentation can also minimize further zonular stress. A symmetrical CCC is ideal for IOL implantation in the sulcus with optic capture. In the present study, we did not detect significant zonular dehiscence preoperatively in either of the eyes of our 68-year-old patient when using AS-OCT (CASIA2 Tomey). However, LenSx AS-OCT revealed zonular dehiscence in both eyes, perioperatively. We created CCC and lens fragmentation without causing stress to the zonules. In the subsequent manual part of procedure, we found zonular dehiscence in the same area as indicated by LenSx AS-OCT, which extended to approximately 200° in the right eye and 180° in the left. After lens fragmentation by LenSx, we successfully removed the lens without further zonular dialysis. However, zonular dialysis (>180°) in the right eye was too large to insert an IOL, either in the capsule or the sulcus. Therefore, we performed scleral IOL implantation. In the left eye, we avoided using capsular tension ring (CTR) for IOL placement to avoid further iatrogenic damage to the zonule. Instead, an IOL was inserted into the sulcus with optic capture to reduce the possibility of further stress to the zonula and phimosis. Post-surgically, the patient regained good eyesight in both eyes. This case illustrates the advantages of FLACS in addressing zonulopathy. The consistent creation of CCC and lens fragmentation by FLACS may increase success rates, even in unexpectedly challenging cases.Keywords: femtosecond laser-assisted cataract surgery, phacodonesis, zonular dialysis, optic capture, anterior segment optical coherent tomography

Details

Language :
English
ISSN :
1179142X
Volume :
ume 12
Database :
Directory of Open Access Journals
Journal :
International Medical Case Reports Journal
Publication Type :
Academic Journal
Accession number :
edsdoj.5665661fc1274e79a436fcc5bb2140e3
Document Type :
article