Back to Search Start Over

Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis

Authors :
Yasunobu Yamashita
Kensuke Tanioka
Yuki Kawaji
Takashi Tamura
Junya Nuta
Keiichi Hatamaru
Masahiro Itonaga
Takeichi Yoshida
Yoshiyuki Ida
Takao Maekita
Mikitaka Iguchi
Masayuki Kitano
Source :
Gut and Liver, Vol 14, Iss 5, Pp 659-664 (2020)
Publication Year :
2020
Publisher :
Gastroenterology Council for Gut and Liver, 2020.

Abstract

Background/Aims: Rosemont classification (RC) with endoscopic ultrasonography (EUS) is important for diagnosing chronic pancreatitis (CP) but is based only on subjective judgement. EUS shear wave measurement (EUS-SWM) is a precise modality based on objective judgment, but its usefulness has not been extensively studied yet. This study evaluated the utility of EUS-SWM for diagnosing CP and estimating CP severity by determining the presence of endocrine dysfunction along with diabetes mellitus (DM). Methods: Between June 2018 and December 2018, 52 patients who underwent EUS and EUS-SWM were classified into two groups according to RC: non-CP (indeterminate CP and normal) and CP (consistent and suggestive of CP). The EUSSWM value by shear wave velocity was evaluated with a median value. The EUS-SWM value was compared with RC and the number of EUS features. The diagnostic accuracy and cutoff value of EUS-SWM for CP and DM and its sensitivity and specificity were calculated. Results: The EUS-SWM value significantly positively correlated with the RC and the number of EUS features. The EUS-SWM values that were consistent and suggestive of CP were significantly higher than that of normal. The area under the receiver operating characteristic (AUROC) curve for the diagnostic accuracy of EUS-SWM for CP was 0.97. The cutoff value of 2.19 had 100% sensitivity and 94% specificity. For endocrine dysfunction in CP, the AUROC was 0.75. The cutoff value of 2.78 had 70% sensitivity and 56% specificity. Conclusions: EUS-SWM provides an objective assessment and can be an alternative diagnostic tool for diagnosing CP. EUS-SWM may also be useful for predicting the presence of endocrine dysfunction.

Details

Language :
English
ISSN :
19762283
Volume :
14
Issue :
5
Database :
Directory of Open Access Journals
Journal :
Gut and Liver
Publication Type :
Academic Journal
Accession number :
edsdoj.56283457f67640c58127aebcd5fb16c0
Document Type :
article
Full Text :
https://doi.org/10.5009/gnl19170