Back to Search Start Over

Determination of distortion corrections for a fixed length optical cavity pressure standard

Authors :
Jacob Ricker
Kevin O. Douglass
Jay Hendricks
Sarah White
Sergei Syssoev
Source :
Measurement: Sensors, Vol 18, Iss , Pp 100286- (2021)
Publication Year :
2021
Publisher :
Elsevier, 2021.

Abstract

Optical gas refractometry has enabled new pressure standards to be developed based on a dual Fixed Length Optical Cavity (FLOC) system. NIST in CRADA (collaboration research and development agreement) partnership with MKS Instruments has created a portable FLOC pressure standard based on gas refractivity. A key challenge for accurate measurements is the characterization of cavity distortions when pressurized. A method for determination of the distortion constants is presented based on using two gases of known refractive index. Using this two-gas technique, the distortions on the portable FLOC pressure standard are corrected so that this correction contributes no more than 1 μPa/Pa of uncertainty (k = 1).

Details

Language :
English
ISSN :
26659174
Volume :
18
Issue :
100286-
Database :
Directory of Open Access Journals
Journal :
Measurement: Sensors
Publication Type :
Academic Journal
Accession number :
edsdoj.55ff86d8010d45b1a6932ac0272c32f2
Document Type :
article
Full Text :
https://doi.org/10.1016/j.measen.2021.100286