Back to Search Start Over

Rotational Atherectomy Induced Coronary Perforation of Right Coronary Artery Draining into Middle Cardiac Vein

Authors :
Amit Hooda, MD
Reza Masoomi, MD
Tarun Jain, MD
Gurpreet S. Johal, MD
Nitin Barman, MD
Samin K. Sharma, MD
Source :
JACC: Case Reports, Vol 2, Iss 11, Pp 1688-1691 (2020)
Publication Year :
2020
Publisher :
Elsevier, 2020.

Abstract

Ellis Type III cavity spilling coronary perforation is a rare complication. We report to our knowledge, the first case of rotational atherectomy induced Type III cavity spilling coronary perforation of right posterior descending artery draining into middle cardiac vein, successfully managed by covered stent deployment. (Level of Difficulty: Advanced.)