Shear Wave Elastography versus Strain Elastography in Diagnosing Parathyroid Adenomas

Authors :
Laura Cotoi
Daniela Amzar
Ioan Sporea
Andreea Borlea
Dan Navolan
Flore Varcus
Dana Stoian
Source :
International Journal of Endocrinology, Vol 2020 (2020)
Publication Year :
2020
Publisher :
Hindawi Limited, 2020.

Abstract

Objectives. The aim of the study was to compare elastographic means in parathyroid adenomas, using shear wave elastography and strain elastography. Methods. This prospective study examined 20 consecutive patients diagnosed with primary hyperparathyroidism and parathyroid adenoma, confirmed by biochemical assay, technetium-99 sestamibi scintigraphy, and pathology report, after parathyroid surgery. All patients were examined on conventional 2B ultrasound, 2D shear wave elastography, and strain elastography. We determined using 2D shear wave elastography (SWE) the elasticity index (EI) in parathyroid adenoma, thyroid parenchyma, and surrounding muscle and examined using strain elastography the parathyroid adenoma, and determined the strain ratio with the thyroid tissue and muscle tissue. Results. All patients had positive sestamibi scintigraphy and underwent surgery, with confirmation of parathyroid adenoma in all cases. The mean parathormone (PTH) value before surgery was 153.29 pg/ml (36.5, 464.8) and serum calcium concentration was 10.5 mg/dl (9, 11.5). We compared using 2D-SWE and strain elastography parathyroid adenoma with thyroid tissue and with surrounding muscle. The mean EI measured by SWE in parathyroid adenoma was 4.74 ± 2.74 kPa and in thyroid parenchyma was 11.718 ± 4.206 kPa (mean difference = 6.978 kPa, p

Details

Language :
English
ISSN :
16878337 and 16878345
Volume :
2020
Database :
Directory of Open Access Journals
Journal :
International Journal of Endocrinology
Publication Type :
Academic Journal
Accession number :
edsdoj.55797fa5701540d9be0657975f5ebb3d
Document Type :
article
Full Text :
https://doi.org/10.1155/2020/3801902