Back to Search
Start Over
A novel method for measuring the diffusion, partition and convective mass transfer coefficients of formaldehyde and VOC in building materials.
- Source :
- PLoS ONE, Vol 7, Iss 11, p e49342 (2012)
- Publication Year :
- 2012
- Publisher :
- Public Library of Science (PLoS), 2012.
-
Abstract
- The diffusion coefficient (D(m)) and material/air partition coefficient (K) are two key parameters characterizing the formaldehyde and volatile organic compounds (VOC) sorption behavior in building materials. By virtue of the sorption process in airtight chamber, this paper proposes a novel method to measure the two key parameters, as well as the convective mass transfer coefficient (h(m)). Compared to traditional methods, it has the following merits: (1) the K, D(m) and h(m) can be simultaneously obtained, thus is convenient to use; (2) it is time-saving, just one sorption process in airtight chamber is required; (3) the determination of h(m) is based on the formaldehyde and VOC concentration data in the test chamber rather than the generally used empirical correlations obtained from the heat and mass transfer analogy, thus is more accurate and can be regarded as a significant improvement. The present method is applied to measure the three parameters by treating the experimental data in the literature, and good results are obtained, which validates the effectiveness of the method. Our new method also provides a potential pathway for measuring h(m) of semi-volatile organic compounds (SVOC) by using that of VOC.
Details
- Language :
- English
- ISSN :
- 19326203
- Volume :
- 7
- Issue :
- 11
- Database :
- Directory of Open Access Journals
- Journal :
- PLoS ONE
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.54d3abc12b524c9fa8778cbe263bdf7c
- Document Type :
- article
- Full Text :
- https://doi.org/10.1371/journal.pone.0049342