Back to Search
Start Over
The Effect of Acromioplasty on the Critical Shoulder Angle and Acromial Index
- Source :
- Arthroscopy, Sports Medicine, and Rehabilitation, Vol 2, Iss 5, Pp e623-e628 (2020)
- Publication Year :
- 2020
- Publisher :
- Elsevier, 2020.
-
Abstract
- Purpose: To evaluate the effect of acromioplasty using a cutting block technique on bony coverage as measured by the critical shoulder angle (CSA) and acromial index (AI). Methods: This study is a retrospective radiographic review using data from a previous prospective randomized clinical trial that offered enrollment to patients aged 18 years or older with a full-thickness tear of the superior rotator cuff between October 2007 and January 2011. Each patient was allocated to repair with either acromioplasty using a cutting block technique or non-acromioplasty treatment arms in a blinded fashion. Medical and demographic information was recorded for each patient. Between January 2017 and December 2017, patients were contacted for repeat follow-up clinical evaluation and radiographs. Measurements of acromial index and critical shoulder angle were performed on pre- and postoperative radiographs by a single reviewer. Results: Seventy-one (75%) patients were available for follow up. The 2 groups were similar in terms of baseline demographics and acromial type. When compared with preoperative measures, acromioplasty did not result in significant reductions in mean CSA (34.5° vs 35.5°; P = .293) or AI (0.68 vs 0.66; P = .283). Furthermore, postoperative CSA (34.5° vs 36.2°, P = .052) and AI (0.66 vs 0.67, P = .535) demonstrated no statistically significant differences between patients with and without acromioplasty, respectively. Conclusions: There was no statistically significant change in either the CSA or AI following acromioplasty, nor was there a significant postoperative difference in CSA or AI between the group that underwent acromioplasty and the group that did not. Clinical Relevance: Some studies suggest a greater postoperative CSA may result in greater risk of retear after arthroscopic rotator cuff repair. The CSA and AI may not be modifiable with acromioplasty.
- Subjects :
- Sports medicine
RC1200-1245
Subjects
Details
- Language :
- English
- ISSN :
- 2666061X
- Volume :
- 2
- Issue :
- 5
- Database :
- Directory of Open Access Journals
- Journal :
- Arthroscopy, Sports Medicine, and Rehabilitation
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.524957a66232493b9255078726ff0f2a
- Document Type :
- article
- Full Text :
- https://doi.org/10.1016/j.asmr.2020.07.012