Back to Search Start Over

Validating device-based physical activity indicators with observation physical activity indicators in Swiss pre-school children

Authors :
Bianca Celine Schmidli
Simon Endes
Sonja D. Stoffel Kerr
Claudio R. Nigg
Source :
Current Issues in Sport Science, Vol 8, Iss 2 (2023)
Publication Year :
2023
Publisher :
Bern Open Publishing, 2023.

Abstract

Purpose Accelometry is a very important tool to measure physical activity (PA) in preschoolers, as it can measure 24-hour PA and detect activity which cannot be captured by other methods. However, accelerometer validation for preschoolers is lacking (Altenburg et al. 2022). Specifically, for the ActiGraph wGT3X-BT and Move 4 (ActiGraph LLC; Move4 activity sensor, movisens GmbH) only a few, respectively no preschooler validation studies, were found. Thus, the purpose was to validate these two accelerometers in Swiss preschoolers with the System for Observing Children’s Activity and Relationships during Play (SOCARP; Ridgers et al., 2010). Methods and Design Preschoolers (2-5 years old) from two Swiss Sunday activity programs (MiniMove & Ä Halle wo’s fägt) were randomly selected as part of a larger program evaluation. PA was assessed SOCARP for a duration of 12 minutes per child. During the observation, the children wore both an ActiGraph and a Move4 device taped to their right hip to record steps. Step-counts from the ActiGraph and Move4 were correlated with each other and with moderate-to-vigorous (MV)PA from SOCARP (as SOCARP does not count steps). Results Valid PA data was available for 45/58 (77.6%) children (49% girls) for SOCARP and for 47/58 (81%) children (51% girls) for accelometry. Step count correlations between the accelerometers (Actigraph and Move4) and %MVPA (SOCARP) was medium and positive (r(43) = .34, p = .03 and r(43) = .37, p = .02; respectively). There was a strong step count correlation between the two devices (r(45) = .90, p < .001), although ActiGraph measured significantly more steps than Move4 (m = 557.74, SD = 255.77 versus m = 397.81, SD = 164.10); t(46)=8.47, p < .001). Discussion PA measurement in preschool children can be challenging. However, the correlation between step counts and observed %MVPA indicates criterion validity for both devices. The step-counts of Actigraph and Move4 validate each other, but there is a difference in the absolute number of measured steps. Due to different outcome parameters, calculation algorithms, and inaccessibility to raw acceleration the comparison of the two devices on movement intensity was not possible. Although promising preliminary indications of validity of device-based measurement of PA in Swiss preschool children, further investigations into the methodological approaches of comparing measurements of movement intensity are warranted. References Altenburg, T. M., de Vries, L., op den Buijsch, R., Eyre, E., Dobell, A., Duncan, M., & Chinapaw, M. J. M. (2022). Cross-validation of cut-points in preschool children using different accelerometer placements and data axes. Journal of Sports Sciences, 40(4), 379-385. https://doi.org/10.1080/02640414.2021.1994726 Ridgers, N. D., Stratton, G., & McKenzie, T. L. (2010). Reliability and validity of the system for observing children’s activity and relationships during play (SOCARP). Journal of Physical Activity and Health, 7(1), 17–25. https://doi.org/10.1123/jpah.7.1.17

Details

Language :
English
ISSN :
24146641
Volume :
8
Issue :
2
Database :
Directory of Open Access Journals
Journal :
Current Issues in Sport Science
Publication Type :
Academic Journal
Accession number :
edsdoj.521a89a92459411582e0e9b74241f3a8
Document Type :
article
Full Text :
https://doi.org/10.36950/2023.2ciss070