Back to Search Start Over

Minimally Invasive Method of Measuring Anti-Müllerian Hormone Level in Dried Blood Spots of Indonesian Infertile Population

Authors :
Ivan Sini
Nining Handayani
Ricky Tjahjadi
Tri Aprilliana Wulandari
Szeifoul Afadlal
Arie Adrianus Polim
Batara Sirait
Irham Suheimi
Arief Boediono
Source :
Fertility & Reproduction, Vol 06, Iss 01, Pp 42-48 (2024)
Publication Year :
2024
Publisher :
World Scientific Publishing, 2024.

Abstract

This study aims to evaluate the certainty of anti-Müllerian hormone (AMH) levels in dried blood spots (DBS) compared to serum AMH. A total of 109 infertile women who planned to undergo their controlled ovarian stimulation cycle were recruited. Serum and DBS samples were collected from each patient for the quantification of AMH levels. Serum AMH was measured with an automated clinical chemistry assay (Roche) while DBS AMH was measured using the Ansh Labs DBS AMH ELISA reagent kit. Mean AMH level in DBS was [Formula: see text][Formula: see text]ng/mL, which ranged from 0.01 to 17.3[Formula: see text]ng/mL, while the mean AMH in serum samples was [Formula: see text][Formula: see text]ng/mL (0.01–10.8[Formula: see text]ng/mL). Comparable accuracy for low AMH quantification was observed between the two methods over basal antral follicle counts (AFC) as a clinical comparator (AUC 86%, cutoff [Formula: see text][Formula: see text]ng/mL, [Formula: see text], [Formula: see text] vs. 85%, cutoff [Formula: see text][Formula: see text]ng/mL, [Formula: see text], [Formula: see text], respectively for DBS and serum sample). Likewise, DBS AMH achieved high concordance for low AMH discrimination in comparison to serum AMH method (AUC 99% vs. 93%, respectively). A strong linear Spearman regression ([Formula: see text], [Formula: see text]) and sufficient agreement (94.5%, mean difference of −1.6, 2.7 to −5.9) was demonstrated among studied groups with mathematical Passing and Bablok regression equation of [Formula: see text]. The confidence interval of intercept (−0.12, 95% CI [−0.29 to −0.01]) and slope (1.80, 95% CI [1.66–1.94]) indicated a constant and proportional difference between the two methods but it was not significant ([Formula: see text]). AMH measurement in DBS could be useful as an alternative approach to screening ovarian reserve through a more convenient remote sample collection.

Details

Language :
English
ISSN :
26613182 and 26613174
Volume :
06
Issue :
01
Database :
Directory of Open Access Journals
Journal :
Fertility & Reproduction
Publication Type :
Academic Journal
Accession number :
edsdoj.519e3980d824b179bd6211550f20095
Document Type :
article
Full Text :
https://doi.org/10.1142/S2661318224500063