Measurement of Phacoemulsification Vacuum Pressure in the Oertli CataRhex3

Authors :
Peterson JS
Cooper C
Ungricht EL
Mamalis C
Barlow W
Zaugg B
Bernhisel AA
Olson RJ
Pettey JH
Source :
Clinical Ophthalmology, Vol Volume 16, Pp 1731-1737 (2022)
Publication Year :
2022
Publisher :
Dove Medical Press, 2022.

Abstract

John S Peterson,1,2 Caitlynn Cooper,1,2 Emilie L Ungricht,1,2 Christina Mamalis,1 William Barlow,1 Brian Zaugg,1 Ashlie A Bernhisel,1 Randall J Olson,1 Jeff H Pettey1 1Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA; 2University of Utah School of Medicine, Salt Lake City, UT, 84132, USACorrespondence: Jeff H Pettey, Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA, Tel +1 801 581 2352, Fax +1 801 581 3357, Email jeff.pettey@hsc.utah.eduPurpose: To determine the actual vacuum pressure generated by the Oertli CataRhex 3® (Oertli), using an external measuring system.Methods: The effective vacuum pressure created by the Oertli was measured with a pressure device that was continuous with the vacuum tubing system while closed to the external environment. Measurements were taken with the machine set to 300 and 500 mmHg at flow rates of 20, 35, and 50 mL/min and at bottle heights of 60, 80, and 100 cm. Pressures were recorded after the foot pedal was depressed to vacuum setting (second position), and the pressure was allowed to stabilize. Subsequently, it was compared to the pressure value displayed by the machine.Results: Externally measured vacuum pressure was on average 13.02% greater (39.05 mmHg) than displayed vacuum pressure at 300 mmHg (P < 0.005) and 8.60% greater (42.98 mmHg) than displayed vacuum at 500 mmHg (P < 0.005). The average difference between displayed and measured pressure increased with increasing bottle heights.Conclusion: On average, the vacuum pressure generated in the Oertli was found to be significantly higher than the machine’s reading when the machine was set at 300 mmHg and 500 mmHg. Adjusting vacuum had variable effects on the measured versus displayed pressure readings.Keywords: phacoemulsification, Oertli CataRhex 3, vacuum pressure, bottle height, flow rate

Details

Language :
English
ISSN :
11775483 and 86754505
Volume :
ume 16
Database :
Directory of Open Access Journals
Journal :
Clinical Ophthalmology
Publication Type :
Academic Journal
Accession number :
edsdoj.51184cde72d34b4d86754505594d16c1
Document Type :
article