MBR and GAC filtration followed by UV disinfection – implications for wastewater reuse at full scale

Authors :
Maria Takman
Catherine J. Paul
Åsa Davidsson
Moa Jinbäck
Stefan Blomqvist
Michael Cimbritz
Source :
Water Reuse, Vol 14, Iss 2, Pp 226-239 (2024)
Publication Year :
2024
Publisher :
IWA Publishing, 2024.

Abstract

Influences of upstream wastewater treatment on the process combination of granular activated carbon (GAC) and ultraviolet (UV) disinfection were studied and the implications of this for wastewater reuse were assessed. GAC is an efficient chemical barrier but contributes little to the removal of indicator bacteria, and generally increases total bacteria concentrations, necessitating disinfection with UV radiation, for example, to ensure the safe reuse of wastewater. The efficiency of UV disinfection is impacted by factors such as particle concentration and UV absorbance of the water and is thus affected by upstream treatment processes. A full-scale wastewater treatment plant with a membrane bioreactor (MBR) followed by GAC filtration was compared to a treatment plant with a conventional activated sludge process and sand filtration, followed by GAC filtration. The removal of indicator bacteria was higher by the GAC filter that was preceded by an MBR. A UV fluence of 400 J/m2 was sufficient to reach irrigation water quality for both process combinations and to meet the criteria for microbial drinking water quality in the MBR + GAC effluent. One sample was selected for chemical analysis, comprising approximately 100 parameters, demonstrating that the MBR + GAC + UV (400 J/m2) effluent met all drinking water criteria except for nitrate levels. HIGHLIGHTS Reuse of wastewater from the full-scale GAC process with subsequent ultraviolet (UV) disinfection.; Removal of indicator bacteria and fungi by GAC filters.; Higher removal of microbial contaminants by a GAC filter downstream membrane bioreactor (MBR) versus CAS + sand filtration.; Chemical and microbial drinking water criteria were met for effluent from MBR + GAC + UV.; UV fluence of 400 J/m2 on MBR + GAC effluent sufficient to meet drinking water criteria.;

Details

Language :
English
ISSN :
27096092 and 27096106
Volume :
14
Issue :
2
Database :
Directory of Open Access Journals
Journal :
Water Reuse
Publication Type :
Academic Journal
Accession number :
edsdoj.5117f2815941471b89abd2d5aeb83ed0
Document Type :
article
Full Text :
https://doi.org/10.2166/wrd.2024.009