Back to Search Start Over

Pollution status and distribution characteristics of indoor air bacteria in subway stations and compartments in a city of Central South China

Authors :
Shuyan CHENG
Zhuojia GUI
Liqin SU
Guozhong TIAN
Tanxi GE
Jiao LUO
Ranqi SHAO
Feng LI
Weihao XI
Chunliang ZHOU
Wei PENG
Minlan PENG
Min YANG
Bike ZHANG
Xianliang WANG
Xiaoyuan YAO
Source :
环境与职业医学, Vol 41, Iss 7, Pp 801-806 (2024)
Publication Year :
2024
Publisher :
Editorial Committee of Journal of Environmental and Occupational Medicine, 2024.

Abstract

BackgroundBacteria are the most diverse and widely sourced microorganisms in the indoor air of subway stations, where pathogenic bacteria can spread through the air, leading to increased health risks. ObjectiveTo understand the status and distribution characteristics of indoor air bacterial pollution in subway stations and compartments in a city of Central South China, and to provide a scientific basis for formulating intervention measures to address indoor air bacteria pollution in subways. MethodsThree subway stations and the compartments of trains parking there in a city in Central South China were selected according to passenger flow for synchronous air sampling and monitoring. Temperature, humidity, wind speed, carbon dioxide (CO2), fine particulate matter (PM2.5), and inhalable particulate matter (PM10) were measured by direct reading method. In accordance with the requirements of Examination methods for public places-Part 3: Airborne microorganisms (GB/T 18204.3-2013), air samples were collected at a flow rate of 28.3 L·min−1, and total bacterial count was estimated. Bacterial microbial species were identified with a mass spectrometer and pathogenic bacteria were distinguished from non-pathogenic bacteria according to the Catalogue of pathogenic microorganisms transmitted to human beings issued by National Health Commission. Kruskal-Wallis H test was used to compare the subway hygiene indicators in different regions and time periods, and Bonferroni test was used for pairwise comparison. Spearman correlation test was used to evaluate the correlation between CO2 concentration and total bacterial count. ResultsThe pass rates were 100.0% for airborne total bacteria count, PM2.5, and PM10 in the subway stations and train compartments, 94.4% for temperature and wind speed, 98.6% for CO2, but 0% for humidity. The overall median (P25, P75) total bacteria count was 177 (138,262) CFU·m−3. Specifically, the total bacteria count was higher in station halls than in platforms, and higher during morning peak hours than during evening peak hours (P

Details

Language :
English, Chinese
ISSN :
20959982
Volume :
41
Issue :
7
Database :
Directory of Open Access Journals
Journal :
环境与职业医学
Publication Type :
Academic Journal
Accession number :
edsdoj.4e2ad6bb6dc64b23a2412cffd1409431
Document Type :
article
Full Text :
https://doi.org/10.11836/JEOM24010