Back to Search
Start Over
Treatment of a Mature Landfill Leachate: Comparison between Homogeneous and Heterogeneous Photo-Fenton with Different Pretreatments
- Source :
- Water, Vol 11, Iss 9, p 1849 (2019)
- Publication Year :
- 2019
- Publisher :
- MDPI AG, 2019.
-
Abstract
- This study focuses on the treatment of a mature landfill leachate by coagulation and photo-Fenton at different conditions. Optimal coagulation is carried out with ferric chloride in acid conditions; and with alum in near-neutral conditions, to minimize the use of sulphuric acid for pH adjustment (1 g/L vs. 7.2 g/L), the generation of sludge and the increase of conductivity in the final effluent. In both cases, a similar chemical oxygen demand (COD) removal is obtained, higher than 65%, which is high enough for a subsequent photo-Fenton treatment. However, the removal of absorbance at 254 nm (UV-254) was significantly higher with ferric chloride (83% vs. 55%), due to the important removal of humic acids at acid pH. The best results for coagulation are 2 g/L ferric chloride at initial pH = 5 and 5 g/L alum at initial pH = 7. After coagulation with ferric chloride, the final pH (2.8) is adequate for a homogeneous photo-Fenton using the remaining dissolved iron (250 mg/L). At these conditions, using a ratio H2O2/COD = 2.125 and 30 min contact time, the biodegradability increased from 0.03 to 0.51. On the other hand, the neutral pH after alum coagulation (6.7) allows the use of zero valent iron (ZVI) heterogeneous photo-Fenton. In this case, a final biodegradability of 0.32 was obtained, after 150 min, using the same H2O2/COD ratio. Both treatments achieved similar results, with a final COD, UV-254 and color removal greater than 90%. However, the economic assessment shows that the approach of ferric chloride + homogeneous photo-Fenton is much cheaper (6.4 €/m3 vs. 28.4 €/m3). Although the discharge limits are not achieved with the proposed combination of treatments, the significant increase of the pre-treated leachate biodegradability allows achieving the discharge limits after a conventional biological treatment such as sequencing batch reactor, which would slightly increase the total treatment cost.
Details
- Language :
- English
- ISSN :
- 20734441
- Volume :
- 11
- Issue :
- 9
- Database :
- Directory of Open Access Journals
- Journal :
- Water
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.4d93faf6673040db96ea21a7c2f17629
- Document Type :
- article
- Full Text :
- https://doi.org/10.3390/w11091849