Back to Search Start Over

Standardisation of data from real-time quantitative PCR methods – evaluation of outliers and comparison of calibration curves

Authors :
Burns Malcolm J
Nixon Gavin J
Foy Carole A
Harris Neil
Source :
BMC Biotechnology, Vol 5, Iss 1, p 31 (2005)
Publication Year :
2005
Publisher :
BMC, 2005.

Abstract

Abstract Background As real-time quantitative PCR (RT-QPCR) is increasingly being relied upon for the enforcement of legislation and regulations dependent upon the trace detection of DNA, focus has increased on the quality issues related to the technique. Recent work has focused on the identification of factors that contribute towards significant measurement uncertainty in the real-time quantitative PCR technique, through investigation of the experimental design and operating procedure. However, measurement uncertainty contributions made during the data analysis procedure have not been studied in detail. This paper presents two additional approaches for standardising data analysis through the novel application of statistical methods to RT-QPCR, in order to minimise potential uncertainty in results. Results Experimental data was generated in order to develop the two aspects of data handling and analysis that can contribute towards measurement uncertainty in results. This paper describes preliminary aspects in standardising data through the application of statistical techniques to the area of RT-QPCR. The first aspect concerns the statistical identification and subsequent handling of outlying values arising from RT-QPCR, and discusses the implementation of ISO guidelines in relation to acceptance or rejection of outlying values. The second aspect relates to the development of an objective statistical test for the comparison of calibration curves. Conclusion The preliminary statistical tests for outlying values and comparisons between calibration curves can be applied using basic functions found in standard spreadsheet software. These two aspects emphasise that the comparability of results arising from RT-QPCR needs further refinement and development at the data-handling phase. The implementation of standardised approaches to data analysis should further help minimise variation due to subjective judgements. The aspects described in this paper will help contribute towards the development of a set of best practice guidelines regarding standardising handling and interpretation of data arising from RT-QPCR experiments.

Subjects

Subjects :
Biotechnology
TP248.13-248.65

Details

Language :
English
ISSN :
14726750
Volume :
5
Issue :
1
Database :
Directory of Open Access Journals
Journal :
BMC Biotechnology
Publication Type :
Academic Journal
Accession number :
edsdoj.4b30f56a6e64429694103de126a2eeea
Document Type :
article
Full Text :
https://doi.org/10.1186/1472-6750-5-31