Back to Search Start Over

Clinical Observation of UreTron Single-Probe Ultrasonic Intracorporeal Lithotripter for Ureteral Calculi

Authors :
Zhang P
Han XW
Zhang X
Zhu XH
Li T
Li YS
Chen YH
Li G
Source :
International Journal of General Medicine, Vol Volume 14, Pp 4229-4237 (2021)
Publication Year :
2021
Publisher :
Dove Medical Press, 2021.

Abstract

Peng Zhang, Xiu-Wu Han, Xin Zhang, Xu-Hui Zhu, Tao Li, Yan-Sheng Li, Yuan-Hao Chen, Gao Li Department of Urology, Beijing Chao-Yang Hospital, Beijing, People’s Republic of ChinaCorrespondence: Xiu-Wu HanDepartment of Urology, Beijing Chao-Yang Hospital, Capital Medical University, 5 Jingyuan Road, Shijingshan District, Beijing, People’s Republic of ChinaTel +86 10-13501356960Email hanxiuwu47859@163.comObjective: The present study aimed to observe and discuss the effectiveness and safety of the UreTron single-probe ultrasonic intracorporeal lithotripter in ureteroscopic lithotripsy.Methods: The clinical data of patients with unilateral solitary ureteral calculi treated with ureteroscopic lithotripsy who were hospitalized at the Department of Urology (West District) of Beijing Chaoyang Hospital between March 2016 and August 2020 were selected for retrospective analysis. The patients were divided into the UreTron group (group U) and holmium laser group (group H) according to the lithotripsy method adopted. The operation duration, length of hospital stay, stone clearance rate, proportion of patients requiring flexible ureteroscopy-assisted lithotripsy, and complications were compared between the groups.Results: There was no statistical difference between the groups in terms of the general characteristics, operation duration, or length of hospital stay (P > 0.05). Regarding the stone clearance rate (group U=93.5%; group H=75%), proportion of patients requiring flexible ureteroscopy-assisted lithotripsy (group U=6.5%; group H=27.8%), and incidence of surgical complications (group U=1 case; group H=9 cases), group U was superior to group H, and the differences between the groups were statistically significant (P < 0.05). However, the differences in other complications (cardiocerebral complications and lower extremity thrombosis) were not statistically significant between the groups (P > 0.05).Conclusion: The UreTron system is a new lithotripsy apparatus that is safe and effective for ureteroscopic lithotripsy and has certain advantages in terms of the stone clearance rate, proportion of patients requiring flexible ureteroscopy-assisted lithotripsy, and surgical complications, making it worthy of clinical application.Keywords: UreTron, holmium laser, ureteral calculi, lithotripsy

Details

Language :
English
ISSN :
11787074
Volume :
ume 14
Database :
Directory of Open Access Journals
Journal :
International Journal of General Medicine
Publication Type :
Academic Journal
Accession number :
edsdoj.47465ee02cde450a8ee97d0919afa197
Document Type :
article