Back to Search
Start Over
The Diagnostic Performance of Interleukin-6 and C-Reactive Protein for Early Identification of Neonatal Sepsis
- Source :
- Diagnostics, Vol 10, Iss 11, p 978 (2020)
- Publication Year :
- 2020
- Publisher :
- MDPI AG, 2020.
-
Abstract
- Interleukin-6 (IL-6) and C-reactive protein (CRP) are being used for diagnosis of sepsis. However, studies have reported varying cut-off levels and diagnostic performance. This study aims to investigate the optimal cut-off levels and performance of IL-6 and CRP for the diagnosis of neonatal sepsis. The study was conducted at the University Hospital of Leipzig, Germany from November 2012 to June 2020. A total of 899 neonates: 104 culture proven sepsis, 160 clinical sepsis, and 625 controls were included. Blood culture was performed using BacT/ALERT 3D system. IL-6 and CRP were analyzed by electrochemiluminescent immunoassay and immunoturbidimetric assay, respectively. Data were analyzed using SPSS 20 statistical software. Among neonates with proven sepsis, the optimal cut-off value of IL-6 was 313.5 pg/mL. The optimal cut-off values for CRP in 5 days serial measurements (CRP1, CRP2, CRP3, CRP4, and CRP5) were 2.15 mg/L, 8.01 mg/L, 6.80 mg/L, 5.25 mg/L, and 3.72 mg/L, respectively. IL-6 showed 73.1% sensitivity, 80.2% specificity, 37.6% PPV, and 94.8% NPV. The highest performance of CRP was observed in the second day with 89.4% sensitivity, 97.3% specificity, 94.5% PPV, and 98.3% NPV. The combination of IL-6 and CRP showed increase in sensitivity with decrease in specificity. In conclusion, this study defines the optimal cut-off values for IL-6 and CRP. The combination of IL-6 and CRP demonstrated increased sensitivity. The CRP 2 at cut-off 8.01 mg/L showed the highest diagnostic performance for identification of culture negative clinical sepsis cases. We recommend the combination of IL-6 (≥313.5 pg/mL) and CRP1 (≥2.15 mg/L) or IL-6 (≥313.5 pg/mL) and CRP2 (≥8.01 mg/L) for early and accurate diagnosis of neonatal sepsis. The recommendation is based on increased sensitivity, that is, to minimize the risk of any missing cases of sepsis. The CRP2 alone at cut-off 8.01 mg/L might be used to identify clinical sepsis cases among culture negative sepsis suspected neonates in hospital settings.
- Subjects :
- neonatal sepsis
interleukin-6
C-reactive protein
diagnosis
Medicine (General)
R5-920
Subjects
Details
- Language :
- English
- ISSN :
- 20754418
- Volume :
- 10
- Issue :
- 11
- Database :
- Directory of Open Access Journals
- Journal :
- Diagnostics
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.460b2823ed534778a23d52a5accbdf0b
- Document Type :
- article
- Full Text :
- https://doi.org/10.3390/diagnostics10110978