Back to Search Start Over

Studies on Flat Sandwich-type Self-Powered Detectors for Flux Measurements in ITER Test Blanket Modules

Authors :
Raj Prasoon
Angelone Maurizio
Döring Toralf
Eberhardt Klaus
Fischer Ulrich
Klix Axel
Schwengner Ronald
Source :
EPJ Web of Conferences, Vol 170, p 02006 (2018)
Publication Year :
2018
Publisher :
EDP Sciences, 2018.

Abstract

Neutron and gamma flux measurements in designated positions in the test blanket modules (TBM) of ITER will be important tasks during ITER’s campaigns. As part of the ongoing task on development of nuclear instrumentation for application in European ITER TBMs, experimental investigations on self-powered detectors (SPD) are undertaken. This paper reports the findings of neutron and photon irradiation tests performed with a test SPD in flat sandwich-like geometry. Whereas both neutrons and gammas can be detected with appropriate optimization of geometries, materials and sizes of the components, the present sandwich-like design is more sensitive to gammas than 14 MeV neutrons. Range of SPD current signals achievable under TBM conditions are predicted based on the SPD sensitivities measured in this work.

Subjects

Subjects :
Physics
QC1-999

Details

Language :
English
ISSN :
2100014X
Volume :
170
Database :
Directory of Open Access Journals
Journal :
EPJ Web of Conferences
Publication Type :
Academic Journal
Accession number :
edsdoj.43b53bf337ed43fc81be1fea921152d6
Document Type :
article
Full Text :
https://doi.org/10.1051/epjconf/201817002006