Back to Search Start Over

A clinical-radiomics nomogram based on automated segmentation of chest CT to discriminate PRISm and COPD patients

Authors :
TaoHu Zhou
Yu Guan
XiaoQing Lin
XiuXiu Zhou
Liang Mao
YanQing Ma
Bing Fan
Jie Li
WenTing Tu
ShiYuan Liu
Li Fan
Source :
European Journal of Radiology Open, Vol 13, Iss , Pp 100580- (2024)
Publication Year :
2024
Publisher :
Elsevier, 2024.

Abstract

Purpose: It is vital to develop noninvasive approaches with high accuracy to discriminate the preserved ratio impaired spirometry (PRISm) group from the chronic obstructive pulmonary disease (COPD) groups. Radiomics has emerged as an image analysis technique. This study aims to develop and confirm the new radiomics-based noninvasive approach to discriminate these two groups. Methods: Totally 1066 subjects from 4 centers were included in this retrospective research, and classified into training, internal validation or external validation sets. The chest computed tomography (CT) images were segmented by the fully automated deep learning segmentation algorithm (Unet231) for radiomics feature extraction. We established the radiomics signature (Rad-score) using the least absolute shrinkage and selection operator algorithm, then conducted ten-fold cross-validation using the training set. Last, we constructed a radiomics signature by incorporating independent risk factors using the multivariate logistic regression model. Model performance was evaluated by receiver operating characteristic (ROC) curve, calibration curve, and decision curve analyses (DCA). Results: The Rad-score, including 15 radiomic features in whole-lung region, which was suitable for diffuse lung diseases, was demonstrated to be effective for discriminating between PRISm and COPD. Its diagnostic accuracy was improved through integrating Rad-score with a clinical model, and the area under the ROC (AUC) were 0.82(95 %CI 0.79–0.86), 0.77(95 %CI 0.72–0.83) and 0.841(95 %CI 0.78–0.91) for training, internal validation and external validation sets, respectively. As revealed by analysis, radiomics nomogram showed good fit and superior clinical utility. Conclusions: The present work constructed the new radiomics-based nomogram and verified its reliability for discriminating between PRISm and COPD.

Details

Language :
English
ISSN :
23520477
Volume :
13
Issue :
100580-
Database :
Directory of Open Access Journals
Journal :
European Journal of Radiology Open
Publication Type :
Academic Journal
Accession number :
edsdoj.419c464257314a62809425a57fb597af
Document Type :
article
Full Text :
https://doi.org/10.1016/j.ejro.2024.100580