Back to Search Start Over

Permanent pacemaker implantation without fluoroscopy in a pregnant woman with complete atrioventricular block: A case report

Authors :
Ayman Elbadawi
Zainab Arif
Dmitry Chuprun
Mohan Rao
Source :
Indian Pacing and Electrophysiology Journal, Vol 16, Iss 5, Pp 172-174 (2016)
Publication Year :
2016
Publisher :
Elsevier, 2016.

Abstract

A 26-year-old pregnant woman in her first trimester presented with progressive fatigue. Her Electrocardiogram showed second degree heart block (Mobitz type II) with intermittent complete heart block. We decided to proceed with dual-chamber permanent pacemaker implantation using CARTO mapping system to avoid fluoroscopy exposure. A mapping catheter was inserted through the right femoral vein. An electro-anatomical map of cardiac chambers was created using the mapping catheter. Through left axillary vein access, the two pacemaker leads were successfully positioned guided by the electro-anatomical map. No complications were noted post procedure. Pacemaker was functioning appropriately at follow-up visits.

Details

Language :
English
ISSN :
09726292
Volume :
16
Issue :
5
Database :
Directory of Open Access Journals
Journal :
Indian Pacing and Electrophysiology Journal
Publication Type :
Academic Journal
Accession number :
edsdoj.41750a3650745aaaa77a15ab819a1f0
Document Type :
article
Full Text :
https://doi.org/10.1016/j.ipej.2016.11.003