Back to Search Start Over

Treatment of proximal humeral fractures using anatomical locking plate: correlation of functional and radiographic results

Authors :
Antonio Carlos Tenor Junior
Alisson Martins Granja Cavalcanti
Bruno Mota Albuquerque
Fabiano Rebouças Ribeiro
Miguel Pereira da Costa
Rômulo Brasil Filho
Source :
Revista Brasileira de Ortopedia, Vol 51, Iss 3, Pp 261-267 (2016)
Publication Year :
2016
Publisher :
Thieme Revinter Publicações Ltda., 2016.

Abstract

ABSTRACT OBJECTIVE: To correlate the functional outcomes and radiographic indices of proximal humerus fractures treated using an anatomical locking plate for the proximal humerus. METHODS: Thirty-nine patients with fractures of the proximal humerus who had been treated using an anatomical locking plate were assessed after a mean follow-up of 27 months. These patients were assessed using the University of California Los Angeles (UCLA) score and their range of motion was evaluated using the method of the American Academy of Orthopedic Surgeons on the operated shoulder and comparative radiographs on both shoulders. The correlation between radiographic measurements and functional outcomes was established. RESULTS: We found that 64% of the results were good or excellent, according to the UCLA score, with the following means: elevation of 124°; lateral rotation of 44°; and medial rotation of thumb to T9. The type of fracture according to Neer's classification and the patient's age had significant correlations with the range of motion, such that the greater the number of parts in the fracture and the greater the patient's age were, the worse the results also were. Elevation and UCLA score were found to present associations with the anatomical neck-shaft angle in anteroposterior view; fractures fixed with varus deviations greater than 15° showed the worst results (p < 0.001). CONCLUSION: The variation in the neck-shaft angle measurements in anteroposterior view showed a significant correlation with the range of motion; varus deviations greater than 15° were not well tolerated. This parameter may be one of the predictors of functional results from proximal humerus fractures treated using a locking plate.

Details

Language :
English, Portuguese
ISSN :
19824378
Volume :
51
Issue :
3
Database :
Directory of Open Access Journals
Journal :
Revista Brasileira de Ortopedia
Publication Type :
Academic Journal
Accession number :
edsdoj.3fd3dfe2e88f46f4b6b25ef93674c7dc
Document Type :
article
Full Text :
https://doi.org/10.1016/j.rboe.2015.08.018