Back to Search Start Over

Lung CT stabilization with high-frequency non-invasive ventilation (HF-NIV) and breath-hold (BH) in lung nodule assessment by PET/CT

Authors :
Mario Jreige
Emeline Darçot
Alban Lovis
Julien Simons
Marie Nicod-Lalonde
Niklaus Schaefer
Flore Buela
Olivier Long
Catherine Beigelman-Aubry
John O. Prior
Source :
European Journal of Hybrid Imaging, Vol 7, Iss 1, Pp 1-10 (2023)
Publication Year :
2023
Publisher :
SpringerOpen, 2023.

Abstract

Abstract Purpose To evaluate the effect of lung stabilization using high-frequency non-invasive ventilation (HF-NIV) and breath-hold (BH) techniques on lung nodule detection and texture assessment in PET/CT compared to a free-breathing (FB) standard lung CT acquisition in PET/CT. Materials and methods Six patients aged 65 ± 7 years, addressed for initial assessment of at least one suspicious lung nodule with 18F-FDG PET/CT, underwent three consecutive lung PET/CT acquisitions with FB, HF-NIV and BH. Lung nodules were assessed on all three CT acquisitions of the PET/CT and characterized for any size, volume and solid/sub-solid nature. Results BH detected a significantly higher number of nodules (n = 422) compared to HF-NIV (n = 368) and FB (n = 191) (p

Details

Language :
English
ISSN :
25103636
Volume :
7
Issue :
1
Database :
Directory of Open Access Journals
Journal :
European Journal of Hybrid Imaging
Publication Type :
Academic Journal
Accession number :
edsdoj.3f626a6f259240239bdc73cbf72a2528
Document Type :
article
Full Text :
https://doi.org/10.1186/s41824-023-00175-4