Back to Search
Start Over
Commercial building flooring failure caused by swelling of the foundation layers
- Source :
- MATEC Web of Conferences, Vol 284, p 04003 (2019)
- Publication Year :
- 2019
- Publisher :
- EDP Sciences, 2019.
-
Abstract
- The work describes the damage, testing and method of repairing the flooring. The flooring formed part of a commercial pavilion covering an area of approx. 1200 m2. Significant damage in the form of cracks and elevations of up to a height of almost 80 mm were detected in the flooring. Geodetic, laboratory and geotechnical tests were carried out to determine the causes of the damage. The cause was found to be swelling of the floor base course layers, consisting of embankments made of unburnt colliery shale mixed with ashes. The swelling processes ceased about 5 years after the structure was commissioned.
- Subjects :
- Engineering (General). Civil engineering (General)
TA1-2040
Subjects
Details
- Language :
- English, French
- ISSN :
- 2261236X
- Volume :
- 284
- Database :
- Directory of Open Access Journals
- Journal :
- MATEC Web of Conferences
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.3afd1bee70c9488ba7a97ffbdcac1e86
- Document Type :
- article
- Full Text :
- https://doi.org/10.1051/matecconf/201928404003