Back to Search Start Over

Development and validation of four one-step real-time RT-LAMP assays for specific detection of each dengue virus serotype.

Authors :
Benjamin Lopez-Jimena
Michaël Bekaert
Mohammed Bakheit
Sieghard Frischmann
Pranav Patel
Etienne Simon-Loriere
Louis Lambrechts
Veasna Duong
Philippe Dussart
Graham Harold
Cheikh Fall
Oumar Faye
Amadou Alpha Sall
Manfred Weidmann
Source :
PLoS Neglected Tropical Diseases, Vol 12, Iss 5, p e0006381 (2018)
Publication Year :
2018
Publisher :
Public Library of Science (PLoS), 2018.

Abstract

4 one-step, real-time, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays were developed for the detection of dengue virus (DENV) serotypes by considering 2,056 full genome DENV sequences. DENV1 and DENV2 RT-LAMP assays were validated with 31 blood and 11 serum samples from Tanzania, Senegal, Sudan and Mauritania. DENV3 and DENV4 RT-LAMP assays were validated with 25 serum samples from Cambodia.4 final reaction primer mixes were obtained by using a combination of Principal Component Analysis of the full DENV genome sequences, and LAMP primer design based on sequence alignments using the LAVA software. These mixes contained 14 (DENV1), 12 (DENV2), 8 (DENV3) and 3 (DENV4) LAMP primer sets. The assays were evaluated with an External Quality Assessment panel from Quality Control for Molecular Diagnostics. The assays were serotype-specific and did not cross-detect with other flaviviruses. The limits of detection, with 95% probability, were 22 (DENV1), 542 (DENV2), 197 (DENV3) and 641 (DENV4) RNA molecules, and 100% reproducibility in the assays was obtained with up to 102 (DENV1) and 103 RNA molecules (DENV2, DENV3 and DENV4). Validation of the DENV2 assay with blood samples from Tanzania resulted in 23 samples detected by RT-LAMP, demonstrating that the assay is 100% specific and 95.8% sensitive (positive predictive value of 100% and a negative predictive value of 85.7%). All serum samples from Senegal, Sudan and Mauritania were detected and 3 untyped as DENV1. The sensitivity of RT-LAMP for DENV4 samples from Cambodia did not quite match qRT-PCR.We have shown a novel approach to design LAMP primers that makes use of fast growing sequence databases. The DENV1 and DENV2 assays were validated with viral RNA extracted clinical samples, showing very good performance parameters.

Details

Language :
English
ISSN :
19352727 and 19352735
Volume :
12
Issue :
5
Database :
Directory of Open Access Journals
Journal :
PLoS Neglected Tropical Diseases
Publication Type :
Academic Journal
Accession number :
edsdoj.39caf4f156a741768d1a868612b30348
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pntd.0006381