Back to Search Start Over

Unenhanced computed tomography as a diagnostic tool in suspected pulmonary hypertension: a retrospective cross-sectional pilot study [version 2; peer review: 2 approved]

Authors :
Charlie Elliot
Krit Dwivedi
Dheyaa Alkanfar
Michael Sharkey
Catherine Hill
Thanos Charalampololous
Robin Condliffe
Smitha Rajaram
Andrew J. Swift
David G. Kiely
Christopher S. Johns
Ze Ming Goh
Samual Barnes
Tarik Julius
Source :
Wellcome Open Research, Vol 6 (2024)
Publication Year :
2024
Publisher :
Wellcome, 2024.

Abstract

Background Computed tomography pulmonary angiography (CTPA) has been proposed to be diagnostic for pulmonary hypertension (PH) in multiple studies. However, the utility of the unenhanced CT measurements diagnosing PH has not been fully assessed. This study aimed to assess the diagnostic utility and reproducibility of cardiac and great vessel parameters on unenhanced computed tomography (CT) in suspected pulmonary hypertension (PH). Methods In total, 42 patients with suspected PH who underwent unenhanced CT thorax and right heart catheterization (RHC) were included in the study. Three observers (a consultant radiologist, a specialist registrar in radiology, and a medical student) measured the parameters by using unenhanced CT. Diagnostic accuracy of the parameters was assessed by area under the receiver operating characteristic curve (AUC). Inter-observer variability between the consultant radiologist (primary observer) and the two secondary observers was determined by intra-class correlation analysis (ICC). Results Overall, 35 patients were diagnosed with PH by RHC while 7 patients were not. Main pulmonary arterial (MPA) diameter was the strongest (AUC 0.79 to 0.87) and the most reproducible great vessel parameter. ICC comparing the MPA diameter measurement of the consultant radiologist to the specialist registrar’s and the medical student’s were 0.96 and 0.92, respectively. Right atrial area was the cardiac measurement with highest accuracy and reproducibility (AUC 0.76 to 0.79; ICC 0.980, 0.950) followed by tricuspid annulus diameter (AUC 0.76 to 0.79; ICC 0.790, 0.800). Conclusions MPA diameter and right atrial areas showed high reproducibility. Diagnostic accuracies of these were within the range of acceptable to excellent, and might have clinical value. Tricuspid annular diameter was less reliable and less diagnostic and was therefore not a recommended diagnostic measurement.

Details

Language :
English
ISSN :
2398502X
Volume :
6
Database :
Directory of Open Access Journals
Journal :
Wellcome Open Research
Publication Type :
Academic Journal
Accession number :
edsdoj.382f1f9d45d497a821dab0e95892709
Document Type :
article
Full Text :
https://doi.org/10.12688/wellcomeopenres.16853.2