Back to Search Start Over

Voltammetric Assay of Metformin Hydrochloride Using Pyrogallol Modified Carbon Paste Electrode

Authors :
Ali Kamal Attia
Waheed M Salem
Mona A Mohamed
Source :
Acta Chimica Slovenica, Vol 62, Iss 3, Pp 588-594 (2015)
Publication Year :
2015
Publisher :
Slovenian Chemical Society, 2015.

Abstract

The electrooxidative behavior and determination of metformin hydrochloride, anti-hyperglycemic drug, on a pyrogallol modified carbon paste electrode were investigated using cyclic voltammetry and differential pulse voltammetry. Metformin hydrochloride shows an irreversible oxidation behavior at all pH values of Britton-Robinson buffer (2.0-9.0). The peak current varied linearly in the range comprised between 8.0 x 10-7 and 6.0 x 10-6 mol/Lwith detection limit of 6.63 x 10-8 mol/Land limit of quantification of 2.21 x 10-7 mol/L. The method was proposed for the determination of metformin hydrochloride in dosage forms and urine.

Details

Language :
English
ISSN :
13180207 and 15803155
Volume :
62
Issue :
3
Database :
Directory of Open Access Journals
Journal :
Acta Chimica Slovenica
Publication Type :
Academic Journal
Accession number :
edsdoj.341adf4282fa499c95efb73a676e0705
Document Type :
article
Full Text :
https://doi.org/10.17344/acsi.2014.950