Back to Search Start Over

Avaliação clínica e polissonográfica do aparelho BRD no tratamento da Síndrome da Apneia Obstrutiva do Sono Clinical and polysomnographic assessment of Obstructive Sleep Apnea Syndrome treatment with BRD appliance

Authors :
Cibele Dal-Fabbro
Cauby Maia Chaves Junior
Lia Rita Azeredo Bittencourt
Sergio Tufik
Source :
Dental Press Journal of Orthodontics, Vol 15, Iss 1, Pp 107-117 (2010)
Publication Year :
2010
Publisher :
Dental Press Editora, 2010.

Abstract

OBJETIVOS: este trabalho de pesquisa teve o intuito de realizar uma avaliação clínica e polissonográfica do efeito de um aparelho intraoral (AIO) para tratamento da Síndrome da Apneia Obstrutiva do Sono (SAOS), desenvolvido e testado por duas universidades federais brasileiras. MÉTODOS: a amostra constou de 50 pacientes (idades entre 18 e 65 anos, sendo 33 homens e 17 mulheres) com diagnóstico polissonográfico inicial de SAOS de grau leve e moderado. Todos os pacientes submeteram-se a uma nova avaliação polissonográfica de noite inteira (em uso do AIO) aproximadamente 6 meses após a primeira avaliação. Baseado na diminuição dos eventos respiratórios obstrutivos, obtida com o uso do AIO, os pacientes foram então divididos em bons respondedores (redução de 50% ou mais no índice de apneia e hipopneia (IAH), permanecendo abaixo de 10 eventos/hora) e maus respondedores (IAH permanecendo maior ou igual a 10 eventos/hora). RESULTADOS E CONCLUSÕES: em 54% da amostra o IAH diminuiu para menos de cinco eventos/hora com o uso do AIO; em 38% a redução do IAH foi maior do que 50%, mas permaneceu acima de cinco eventos/hora; e em 6% da amostra o IAH reduziu menos que 50%. Os bons respondedores corresponderam a 86% da amostra estudada, enquanto os maus respondedores a 14%. Houve melhora significativa na escala de sonolência, no IAH, nos microdespertares e na saturação mínima de oxihemoglobina com a terapia utilizada. O Índice de Massa Corpórea elevado parece interferir desfavoravelmente no desempenho do aparelho em estudo.OBJECTIVES: The current investigation aimed to carry out a clinical and polysomnographic assessment of treatment of Obstructive Sleep Apnea Syndrome (OSAS) with an oral appliance (OA) developed and tested by two Brazilian federal universities. METHODOLOGY: The sample was composed of 50 patients (aged between 18 and 65 years, 33 men and 17 women) with initial polysomnographic diagnosis of light to moderate OSAS. All patients underwent a second, full-night polysomnography with the use of the OA approximately 6 months after the first assessment. Based on the reduction of respiratory events obtained with the OA, patients were distributed in good responders (Apnea and Hypopnea Index/AHI under 10 and with reduction of at least 50% in relation to baseline); and poor responders (AHI of 10 or over with OA). RESULTS AND CONCLUSION: In 54% of the sample, AIH reduced to less than five events/hour with OA; in 38% the AHI reduction was more than 50% in relation to baseline (but more than five); and in 6% of the sample, the AHI reduced less than 50%. Good responders corresponded to 86% of the studied sample, while poor responders to 14%. We noticed significant improvement in somnolence, in AIH, in microarousals and also in minimum oxygen saturation with the treatment. Increased body mass index (BMI) seemed to interfere unfavorably in the performance of the OA studied.

Details

Language :
English, Portuguese
ISSN :
21769451 and 21776709
Volume :
15
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Dental Press Journal of Orthodontics
Publication Type :
Academic Journal
Accession number :
edsdoj.340e0f0570fe48e091433aa70517ccef
Document Type :
article
Full Text :
https://doi.org/10.1590/S2176-94512010000100013